Linksys COLONIAL SERIES COL-3629 User Manual

Page 18

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

18

Locking Band

63L60

FLB

Figure 50

FINISH TO YOUR TASTE

There are a wide variety of “finished looks” for
these fireplaces, from formal wall decor with
elaborate mantels to rustic wood paneling or
warm brick facings.

Only noncombustible materials like stone, tile,
brick, etc., may overlap the black front facing.
Do not extend these materials beyond the black
facing and into the firebox area. Be sure not to
interfere with the installation and operation of
glass doors or block the upper or lower grilles.
Seal all joints between the black facing and wall
surrounds to prevent air intrusion. Use non-
combustible caulking material only to seal the
black metal facing to the surround material on
the finished wall.

Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 50.

Offset/ Return
Package (30

°

)

63L23

FTF10-ES30

INSTALLATION COMPONENTS

The following items are available for use in the
installation of this appliance. Separate installa-
tion instructions are packaged with all combus-
tion air kits and chimney terminations.

If you encounter any problems or have ques-
tions concerning the installation or application
of this system, please contact your distributor.
For the name of your nearest distributor call:

LENNOX HEARTH PRODUCTS
1110 West Taft Avenue
Orange, California 92865

4

³⁄₄"

(121mm)

3

¹⁄₄"

(83mm)

18" (457mm)

Min. Distance to

Unprotected Side Wall

12" (305mm)

Min. Distance to

Protected Side Wall

Fireplace

¹⁄₂"

(13mm)

Combustible

Materials Allowed

in Shaded Areas

15

°

Stabilizer

63L26

FTF10-S4

Model

Part Number

Weight

COL-3629

19M22

450 lbs.

COL-3629H

30M31

450 lbs.

Figure 49

7" Max.

(178mm)

Max. Thickness of Hearth
Extension when Fireplace
is on the Floor

The sum of all “R values” is: .70 + .10 +. 038
+ .10 = .938

This would NOT be an acceptable combination
of material for the hearth extension since the
total calculated “R value” of the materials used
is under the required “R value” of 1.19. An
additional layer of insulating materials must
be used.

Note: Also see NFI Certification Manuals for
expanded explanation on calculating “R val-
ues” when multiple materials are used.

WARNING: THE CRACK BETWEEN THE
FIREPLACE AND THE HEARTH EXTEN-
SION MUST BE SEALED WITH A NON-
COMBUSTIBLE MATERIAL.

WARNING: WHEN INSTALLING HEARTH
EXTENSION IN FRONT, THE FIREPLACE
MUST BE RAISED IF HEIGHT OF HEARTH
EXTENSION EXCEEDS 7" (178 MM) ABOVE
THE BOTTOM OF THE FIREPLACE (

SEE

FIGURE 49 ).

Secure the hearth extension to the floor to
prevent possible shifting.

Advertising