Alternate Programming Section

To make it easy for installers familiar with Linear’s and other manufacturer’s
access control systems, two methods of programming are available.
Function Codes that match other equipment help the installer to make
quick programming changes with keystrokes they have used before.

Alternate Programming Method Selection

The Programming Position Numbers (or Function Codes) change
depending on the programming method used. Refer to the table on
Page 13 for the numbers used for each programming method.
The keys used to enter programming from the unit’s keypad select
which programming method is used for the current programming
session.
Entering programming by pressing

&

keys together will select

the Alternate Programming Method (other manufacturer’s style). Details
of each programming step when using the Alternate Programming
Method are shown on Pages 15-21.

Alternate Audio Prompts

The audio prompts that give feedback during programming at the unit’s
keypad or over the telephone are different for the Alternate Programming
Method. Those differences are shown in the table to the right.

Alternate Alphanumeric Entry

When the keypad is used for alphanumeric data entry in the alternate
programming mode, each key enters data differently than the standard
interface mode. See the keypad fi gure to the right.

Alternate Programming Access from the Keypad

1. Press & keys at the same time, then release.
2. The display will show [Master Code:].
3. Enter the master code (factory setting is 123456).
4. The display will show asterisks as the code is entered.
5. If the master code is incorrect, the system will sound two

long beeps and return to normal operating mode.

6. If the password is correct, the display will

show [SELECT FUNCTION:].

7. Programming commands can now be entered on the

keypad. Refer to the following pages in this manual
for Alternate Programming Method step details.

Re-entering a Command After a Mistake

If an incorrect entry, or an incorrect key is pressed during programming, to
clear the keypad press and start the programming step over again.

Exiting Alternate Programming Mode

1. Press:

NOTE: The AE-100 will automatically exit Programming Mode after

fi ve minutes of programming inactivity.

ALTERNATE PROGRAMMING METHOD

AUDIO PROMPTS FOR EACH PROGRAMMING METHOD

CONDITION

ALTERNATE

METHOD

SOUND

STANDARD

METHOD

SOUND

AFTER AN INCORRECT ENTRY

TWO
LONG
BEEPS

ONE
LONG
BEEP

AFTER A CORRECT ENTRY OF AN
INTERIM STEP

ONE
SHORT
BEEP

TWO
SHORT
BEEPS

AFTER A COMPLETE COMMAND
HAS BEEN ENTERED CORRECTLY

TWO
SHORT
BEEPS

THREE
SHORT
BEEPS

EXITING PROGRAMMING MODE

THREE
SHORT
BEEPS

NO
BEEPS
SOUND

Q Z - , . ' *

q z 0 1 2 3

4 5 6 7 8 9

A B C a b c

D E F d e f

space

G H I h g i

P R S p r s

M N O m n o

W X Y w x y

J K L j k l

T U V t u v

erase

entire entry

move to
next letter
or finish

ALTERNATE INTERFACE KEYPAD ALPHANUMERIC ENTRY

(FOR PROGRAMMING STEPS REQUIRING TEXT)

• ENTER # AFTER EACH LETTER TO MOVE TO THE NEXT CHARACTER

• FINISH COMPLETE ENTRY BY ENTERING ##

• PRESS 8 THEN 0 TO BACKSPACE

• PRESS STAR TO ERASE ENTIRE ENTRY

ALTERNATE PROGRAMMING METHOD

PRESS

TOGETHER

AND

FOR