Figure 3, Figure 4, Variable flame height adjustment – Lennox Hearth MLDVTCD-35NE User Manual

Page 9

Advertising
background image

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • MERIT

®

SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION

Electronic Appliances

To light electronic appliances refer to the detailed

lighting instructions found on Pages 22 and

23 of these instructions. Electronic appliance

lighting instructions may also be found on the

pull out lighting instruction labels attached to

the gas control valve.

If your electronic appliance is equipped with an

optional remote wall switch or remote control

kit the appliance main burner may be turned on

and off with the wall switch or remote control.

If your electronic appliance is not equipped with

a wall switch or remote control, the main burner

must be turned off and on with a gas control

switch located in some other location by the

installer. Contact the installer for directions.

Check batteries, if installed, routinely (every

three months).

Note: It is recommended that batteries not

be installed in the battery holder until a power

outage, or if the appliance is to be operated

solely with two (2) "D" batteries.

Refer to the Lighting Instructions on Page 22 to

light the appliance in the event of a power failure.

TO LIGHT YOUR APPLIANCE IN A POWER

OUTAGE DO THE FOLLOWING:

• Install batteries in battery pack.

• Turn unit mounted switch or wall switch to

the ON Position.

• Unit should spark at pilot and light.

• Operate Normally.

• Replace batteries if needed.

• After power is restored, remove batteries.

Figure 3

- SIT Millivolt Gas Valve

Variable Flame

Height Adjustment

Manifold Pressure

Port

Inlet

Pressure

Port

Main Gas Control Knob

H I

LO

W

TPTH

TP

TH

PIL

OT

PI

LO

T

ON

it

OFF

IN

OUT

Gas Inlet

Terminals TPTH, TP and TH

Gas

Outlet

Figure 4

- Dexen Electronic Gas Valve

Variable Flame

Height Adjustment

Manifold Pressure

Port

Inlet

Pressure

Port

Main Gas Control Knob

H I

LO

W

TPTH

TP

TH

PIL

OT

PI

LO

T

ON

it

OFF

IN

OUT

Gas Inlet

Terminals TPTH, TP and TH

Gas

Outlet

Supply Gas

Inlet

Pressure-Tap

(Manifold)

Regulator

Mounting

Screw

Burner Stage

Terminal

Gas

Outlet

To Burner

Ground (TP)

Pilot Stage

Terminal

Pilot Gas Outlet

Pressure-Tap

(Inlet)

PILOT

OUT

VENT

LO

TH TP

TH

TP

HI

IN

IN

Variable Flame Height Adjustment

All millivolt and electronic appliances are

equipped with a variable gas control valve.

Flame height for these models may be adjusted

through a range between fixed low and high

settings while the appliance is in operation.

Adjust the flame height as desired after lighting

the appliance by rotating the variable adjustment

control knob (HI/LO) located on the front of the

valve (refer to Figures 3 and 4).