Lexicon LX Power Amplifier 070-14876 User Manual

Page 17

Advertising
background image

Basic Operation

LX Power Amplifiers

2-9

DC PROTECTION

Each channel includes DC protection to prevent DC and
frequencies below 10Hz from reaching the speakers. If this
protection activates, the output relay will open and the
corresponding front panel channel status LED will no longer be lit.
After approximately 4-seconds, DC protection will be
automatically deactivated. The relay will close and the
corresponding channel status LED will light blue. If DC or
frequencies below 10Hz are still present, DC protection will be
automatically reactivated. The amplifier will continue to engage
this protection until the problem is no longer present.

Advertising