Technical specifications – Lucent Technologies Stinger MS+DSL User Manual

Page 2

Advertising
background image

To learn more, contact your local Lucent
Technologies Representative, Authorized
Reseller, or Sales Agent.

Or, visit our Web site at www.lucent.com

Specifications subject to change
without notice.

This document is for planning purposes
only, and is not intended to create,
modify or supplement any Lucent
Technologies specifications or warranties
relating to these products or services.
Information and/or technical
specifications supplied within this
document do not waive (directly or
indirectly) any rights or licenses –
including but not limited to patents or
other protective rights – of Lucent
Technologies or others.

Stinger and Navis are registered
trademarks of Lucent Technologies.

Copyright © 2005
Lucent Technologies, Inc.

Printed in the U.S.A.

STMS v2.0305

Technical Specifications

Description Specifications

1.Electrical Specifications

Power Requirements:

-48 VDC @ 770 Watts maximum

Inrush:

All modules have inrush limiting circuits

Power Connectors:

x2 M5 Studs per unit

Input Redundancy:

Optional input available

Hot Swappable:

Yes, both inputs can be Hot swapped

2.Physical Specifications

Height:

17.78 cm [7.0 in] [4U]

Width:

44.90 cm [17.7 in]

Depth:

39.00 cm [15.35 in]

Unit Weight:

30 kg [66 lbs] max – (Fully Configured)**

Rack Mount Options:

Forced Air Cooled
Intake/ Exhaust
Fits 19-in, 23-in and ETSI racks with
the appropriate rack mounting ears
not to block airflow

Not to be blocked by more then 20%**

3.Card Slots

Front Access:

4 for line interface modules (LIMs)
1 for control module

Rear Access:

4 for line protection modules:
(LPMs), path selector modules
(PSMa), and/or Copper Loop Test
(CLT) modules

1 for trunk module (TM)

4.Line Interface

50 – pin RJ-21X

5.Trunk Interface

OC-3c/STM-1 optical

Single mode
(standard or long-reach options)
Multimode

DS3/E3

electrical with pass through

OC-12/STM-4
10/100 Ethernet
Gigabit Ethernet

6.Operating Environment

Ambient operating temperature

32° to 131°F (0° to 55°C)

Relative humidity

10% – 95% (non-condensing)

Operating altitude

Up to 4,000m (13,123 ft)

7.Regularity Compliance

Bellcore GR-63-CORE
Bellcore GR-1089-CORE
EN/IEC 60950 (CE)
EN 55022 Class A

EN 300386-2

8.Model Numbers

Stinger MS+Base unit with pre-installed:
19" Rack Mount Kit

(STGRMSP19-UNIT-MODEL)

23" Rack Mount Kit

(STGRMSP23-UNIT-MODEL)

ETSI Rack Mount Kit

(STGRMSPETSI-UNIT-MODEL)

** Estimated

Advertising