Polycom MX392 User Manual

Page 9

Advertising
background image

Now, right click in the A

CTIVATED

C

OMMAND

column for Logic Input 1 and select I

NSERT

, I

NPUT

, 1,

M

UTE

, O

FF

. Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute

Input 1.

Now, right click in the D

EACTIVATED

C

OMMAND

column for Logic Input 1 and select I

NSERT

, I

NPUT

, 1,

M

UTE

, O

N

. Now, whenever the switch goes Active High (+ 5V DC), the Vortex Device will mute

Input 1.

Do not assign any command to the H

ELD

C

OMMAND

column.

If you are successful, you should see this on the screen:

9

Advertising
This manual is related to the following products: