Polycom ViewStation EX4000 User Manual

Page 74

Advertising
background image

Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000

64

www.polycom.com

The PRI T1 needs to be provisioned for the ViewStation FX and
VS4000 systems as follows:

Table 3-4. ISDN PRI Requirements

Line settings

ESF/B8ZS (default)

Extended Super Frame B8ZS is modem standard for
T1/PRI line encoding and framing

Line termination
type

CPE (user side) only

The required termination is built into the system and
most access switches

Supported PRI
switch protocols

AT&T 4ESS, AT&T 5ESS, NI-1, NI-2, Siemens,
Nortel DMS 100, and Nortel 250

These are standard protocols for North America

Number of
channels

23 B-channels dialable at 64 or 56 Kbps, and one D
channel

Ensure that you have 64 Kbps clear channel service

Number of
network
interfaces

1 (single PRI)

Line build-out
modes

DSU+CSU (0 to –22.5dB attenuation), DSU-only
(DSX 0-665 feet)

Physical distance is offset by the settings in the user
interface

Clocking

Must be derived from the external network or the
PBX

Terminal
Endpoint ID
(TEI)

0-63

This identifies the PRI endpoint; the common default
is 0

Numbering

One local directory number per interface (23
channels)

D-channel slot
number

24

Included to verify where the D channel is; this is
where additional diagnostic information resides

Call-by-call
service codes

Values 0-31 service codes for GVPN/PN/UPN
network-specific services

Advertising