Install Outdoor Base Stations

Outdoor Base Stations are equipped with a protective enclosure,

designed to be mounted to a wall or pole. After the enclosure is

mounted, the Base Station is inserted in the enclosure and connected.

Only RCO Base Stations can be used outdoors.

The customer’s wire contractor is responsible for wiring and

mounting the outdoor Base Station enclosure. The contractor is

responsible for supplying screws, brackets, and other appropriate

hardware.

Wire and connect outdoor Base Stations

If the cabling between the MCU and the telephone system or to the
Base Station leaves the building, consult the telephone system
manual, the National Electric Code (NEC), and local codes for
instructions on providing lightning and other over-current
protection.

1. Mount the outdoor Base Station enclosure to a wall or pole. The

enclosure should be attached at the highest point available that

will provide central coverage for the outdoor area.

2. Insert the Base Station cable through the compression fitting and

tighten the fitting.

3. Wire the Base Station connector just as you wired the RJ-45

connectors for the indoor Base Stations.

4. Place the Base Station inside the enclosure with the part number

label facing the back of the enclosure.

5. Screw the protective cover onto the Base Station enclosure.