Connecting cables to the rmx 4000, Connecting cables to the rmx 4000 -17 – Polycom DOC2560C User Manual

Page 49

Advertising
background image

Polycom RMX 1500/2000/4000 Getting Started Guide

2-17

with an appropriate antioxidant compound before crimp connections
are made. Tinned, solder-plated or silver plated connectors do not

have to be prepared in this manner.

6

Replace the transparent plastic caps on the terminal block.

7

Turn ON the Main that supplies power to the RMX.

8

Turn ON the circuit breaker on each of the DC Power Rail Modules.

Connecting Cables to the RMX 4000

To connect the cables (AC and DC systems):

RTM-IP 4000:

Connect the Management Network cable to LAN 2.

Connect the Signalling cable to LAN 3.

Connect the Shelf Management cable to LAN 6.

For each installed RTM LAN - Connect the LAN cable to LAN 2.

For each installed RTM ISDN:

Connect the E1/T1 cables to their PRI Ports.

Connect the LAN cable to LAN 1.

Figure 2-3

RMX 4000 Rear Panel View with AC Power and Communication

Cables

LAN Connections to RTM LAN

Power Cables

Off/On
switch

E1/T1 Connection to RTM ISDN

Shelf
Manage-
ment

Management
Network

Signalling
Network