Command List

Command Set

Command

Command Packet

Comments

Address Set

Broadcast

88 30 01 FF

IF_Clear

Broadcast

88 01 00 01 FF

CommandCancel

81 2p FF

p: Socket No.(=1or2)

CAM_Zoom

Stop

81 01 04 07 00 FF

Tele (Standard)

81 01 04 07 02 FF

Wide (Standard)

81 01 04 07 03 FF

Tele (Variable)

81 01 04 07 2p FF

p=0 (Low) to 7 (high)

Wide (Variable)

81 01 04 07 3p FF

Direct

81 01 04 47 0p 0q 0r 0s FF pqrs: Zoom Position

CAM_DZoom

On

81 01 04 06 02 FF

Digital zoom ON/OFF

Off

81 01 04 06 03 FF

Combine Mode

81 01 04 36 00 FF

Optical/Digital
Zoom Combined

Separate Mode

81 01 04 36 01 FF

Optical/Digital
Zoom Separate

Tele(Variable)

81 01 04 06 2p FF

p=0 (low) to 7 (high)

Wide(Variable)

81 01 04 06 3p FF

x1/Max

81 01 04 06 10 FF

x1/Max Magnification
Switchover

Direct

81 01 04 46 00 00 0p 0q FF pq: D-Zoom Position

CAM_Focus

Stop

81 01 04 08 00 FF

Far (Standard)

81 01 04 08 02 FF

81 01 04 08 03 FF

Far (Variable)

81 01 04 08 2p FF

Near (Variable)

81 01 04 08 3p FF

p=0 (Low) to 7 (high)

Direct

81 01 04 48 0p 0q 0r 0s FF

Auto Focus

81 01 04 38 02 FF

Manual Focus

81 01 04 38 03 FF

Auto/Manual

81 01 04 38 10 FF

One Push Trigger

81 01 04 18 01 FF

Infinity

81 01 04 18 02 FF

Forced infinity

Near Limit

81 01 04 28 0p 0q 0r 0s FF

pqrs: Focus Near
Limit Position

Near (Standard)

pqrs: Focus Position

AF ON/OFF

One Push AF Trigger

Stop

81 01 04 06 00 FF

AF Sensitivity

Normal

Low

81 01 04 58 02 FF

81 01 04 58 03 FF

AF Sensitivity
High/Low

81 01 08 02 01 FF

Camera Power

81 01 08 01 01 FF

Power on

On

81 01 08 01 00 FF

Power off

Laser Power

On

Power on

81 01 08 02 00 FF

Power off

Off

Momentary

81 01 08 02 02 XX FF

XX=time on from
1 to 10 seconds

Off

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

VISCA Camera-Issued Messages

ACK/Completion Messages

Error Messages

Network Change Message

z0 4y FF
(y:Socket No.)

Returned when the command is accepted.

ACK

Completion

z0 5y FF
(y: Socket No.)

Returned when the command has been executed.

z=Device address +8

Command Messages

Comments

Command Messages

Comments

90 60 02 FF

Returned when the command format is different
or when a command with illegal command
parameters is accepted.

Syntax Error

Command Buffer Full

Indicates that two sockets are already being
used (executing two commands) and the
command could not be accepted when received.

90 60 03 FF

Command Cancelled

90 6y 04 FF
(1:Socket No.)

Returned when a command which is being
executed in a socket specified by the cancel
command is canceled. The completion message
for command is not returned.

No Socket

90 6y 05 FF
(1:Socket No.)

Returned when no command is executed in a
socket specified by the cancel command, or
when an invalid socket number is specified.

Command not executable 90 6y 41 FF

Returned when a command cannot be executed
due to current conditions. For example, when
commands controlling the focus manually are
received during auto focus.

(1:Socket No.)

Command Message

Comments

Network Change

z0 38 FF

Issued when power is being routed.