Isdn/pstn clock source, Rmx 1500 power supply, Power supply leds – Polycom RMX DOC2557C User Manual

Page 23: Isdn/pstn clock source -19, Rmx 1500 power supply -19, Power supply leds -19

Advertising
background image

Polycom RMX 1500 Hardware Guide

1-19

ISDN/PSTN Clock Source

Each RTM ISDN 1500 has its own primary and secondary clock source.

The first span to synchronize becomes the primary clock source and the
second span to synchronize becomes the secondary clock source. This

clock is used to synchronize ISDN spans only (it is not the system clock).
A single clock source triggers an alarm that can be turned off by setting

the appropriate flag in the system configuration.

RMX 1500 Power Supply

Subject to availability on the RMX 1500 there are two types of power

supplies (Power-One & Astec), both are identical in their functionality.

Power Supply LEDs

On the RMX 1500 there are three LEDs that indicate the power status.

Table 1-8

Polycom RMX 1500 Power Supply LEDs

Power Supply LED

Description

OK

DC power indication to internal components of the RMX:
Green - DC Power Good.

(Alarm symbol)

Power supply failure Indication:
Amber - Power Supply Failure.

AC/~ (symbol)

Main power supply indication (Voltage In):
Green - Voltage Input > 85 VAC.

Advertising