Figure 3-3. xl power supply and drive connections – Parker Products ViX250AE User Manual

Page 22

Advertising
background image

3. ELECTRICAL INSTALLATION 15

XL-PSU Supply/Drive Connections

When used to supply up to two drives the power supply can be wired as shown in Figure 3-3.

-DC

+24V

P1

P2

N

L

MAINS
INPUT

110V-230V~
50/60 Hz
250VA

Power
Supply
Unit

XL

GND

EXT. BRAKING RES.

+DC (80V)

HV STATUS

BRAKING RES.

24V STATUS

X2

X3

X1

X4

X5

ST

HV

FB

10

1

10

1

10 mm

Mininum spacing
between drives & PSU

L N EARTH (GND.)

The XL_PSU must
be securely earthed

P2 mating socket

If the supply is positioned
this side of the drive
avoid blocking access to
D-type X3

Figure 3-3. XL Power Supply and Drive Connections

Advertising