Replacing the fabric switch module (fsm 4000), Replacing the fabric switch module (fsm 4000) -18, 0), see “ replacing the fabric switch – Polycom RMX DOC2548A User Manual

Page 60

Advertising
background image

Chapter 2- Component Replacement

2-18

Replacing the Fabric Switch Module (FSM 4000)

1

Ensure that the power switch/circuit switch on the RMX 4000 is

turned OFF (O).

2

Loosen the captive screws that fasten the module to the MCU.

3

Remove the Fabric Switch Module (FSM 4000). Use the metal ejector

levers to pull the Fabric Switch Module (FSM 4000) out of its slot in

the backplane.

4

Carefully slide the Fabric Switch Module (FSM 4000) out through the

front panel.

5

On the card to be installed, move the ejector levers to their fully open

position.

6

Slide in the replacement Fabric Switch Module (FSM 4000).

7

Push the Fabric Switch Module (FSM 4000) firmly into the backplane,

making sure it is properly seated in its slots.

8

Ensure that the metal ejector levers are fully retracted into their

housings.

9

Tighten the captive screws on the rear panel of the RMX 4000 that

secure the Fabric Switch Module (FSM 4000).

10 Turn ON the RMX 4000.