Options

99-186

Weatherhoods, Two - 6" c/w
1/4" mesh screen

99-130W

Remote Wall Mount Dehumidistat
Control 24 VAC only

99-RSK6

6” back draft damper

Side

Front

29.5"

19"

47.5"

6"

6"

®

C L E A N A I R F U R N A C E

14"

12"

4"

Top

29.5"

22"

19"

14"

Bottom

29.5"

19"

16"

Duct (coil)
Opening

Optional R/A
Opening

17.25"

Ventilation Supply
Air Inlet

Ventilation Exhaust
Air Outlet

22"

Return Plenum

Latches

Blower Section

(SERVICE CLEARANCE 1')

(SERVICE CLEARANCE 3')

Specifications

Model 40DHWDF

(Down Flow)

Core

Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy
recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for
regions where the temperature does not drop below 25˚F (-4˚C).

Filters

Washable air filters in exhaust and supply air streams of ventilation section, 1" pleated in
return plenum side.

Case

Prepainted galvanized steel for superior corrosion resistance.

Dimensions & Clearances

1030

900
825
740

3 GPM

130

140

150

160

170

180

Water
Temp.

44.0
41.0
38.9
36.5

51.7
48.0
46.7
42.7

59.3
55.1
52.4
49.0

67.0
62.3
59.2
55.3

CFM @ .25"WG

74.8
69.4
66.0
61.7

82.5
76.6
72.8
68.0

4 GPM

130

140

150

160

170

180

48.0
44.1
41.7
38.7

56.2
51.7
48.8
45.5

64.5
59.3
56.0
51.9

72.8
66.9
63.2
58.6

81.2
74.6
70.4
65.3

89.6
82.3
77.6
72.0

5 GPM

130

140

150

160

170

180

50.5
46.1
43.5
40.0

59.1
54.0
50.9
46.9

67.8
61.9
58.3
53.7

76.5
69.8
65.8
60.5

85.3
77.8
73.3
67.4

94.1
85.8
80.8
74.3

890
790
740
660

40.7
38.0
36.5
33.8

47.7
44.5
42.7
39.6

54.8
51.0
49.0
45.5

61.9
57.6
55.3
51.3

CFM @ .5"WG

69.0
64.3
61.7
57.2

76.2
70.9
68.0
63.0

40DHW Output (MBH)

43.8
40.5
38.7
35.6

51.3
47.4
45.3
41.7

58.9
54.4
51.9
47.8

66.5
61.3
58.6
53.9

74.1
68.3
65.3
60.0

81.7
75.4
72.0
66.2

45.7
42.0
40.0
36.7

53.6
49.2
46.8
42.9

61.4
56.4
53.7
49.2

69.3
63.6
60.5
55.4

77.2
70.8
67.4
61.7

85.1
78.0
74.3
68.0

Note: Ventilation ports and return plenum opening available
off either side of cabinet. All units conform to CSA and UL Standards.

40DHWDF Output (MBH)

Model

40DHWDF

Voltage

120 VAC 60 Hz

Hp

1/3

Amps (total)

7

Water

1/2" Copper Soldered

Connections

Connection

Airflow (High)
.25 in wg

1030 CFM

.5 in. wg

890 CFM

Ventilation

100 - 140 CFM

Airflow

Effectiveness

70%

(Aluminum Core)

Total Efficiency

50%

(Enthalpic Core)

Net Weight

150 lbs.

Shipping Weight

165 lbs.

Warranty

Units carry a lifetime warranty on the heat
recovery (aluminum) core, a five year warranty
on the energy recovery (enthalpic) core and a
five year replacement parts warranty on all
other components.

0105