Connect wiring – NuTone QTREN110FLT User Manual

Page 3

Advertising
background image

Page 3

MODELS QTREN080FLT • QTREN110FLT

4. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

1b.Mount housing anywhere between

trusses, joists, or I-joists using hanger

bars.

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be

used on all types of framing (I-joist, standard joist, and truss

construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the

SCREWS supplied. Make sure TABS face “up” as shown. Use

the set of channel mounting holes (marked “STD”) to mount

the housing flush with the bottom of the drywall. Use the other

set of holes (not marked) to mount the housing flush with the

top of the drywall.

HANGER

BAR (4)

SCREWS (4)

TAB

Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping

around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)

through HOLES near nails.

*

To ensure a noise-free mount: Secure hanger bars together

with SCREWS or use a pliers to crimp mounting channels

tightly around hanger bars.

*

SCREW (2)

HOLE FOR OPTIONAL

SCREW MOUNTING (4)

STD

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE

OF FRAMING

2. Attach

damper/duct
connector.

Snap damper /

duct connector

onto housing.

Make sure

connector is flush

with top of housing

and damper flap

falls closed.

3. Install

4-inch
round
ductwork.

Connect 4-inch

round ductwork to

damper / duct

connector. Run

ductwork to a roof

cap or wall cap.

Tape all ductwork

connections to make them secure and air tight.

Advertising