Chapter 7 Troubleshooting Guide
Problems During Backup/Restore Operations

72

LTO-2 Half-Height Tape Drive User’s Guide

1

The

TapeAlert

message or backup log shows,

“The operation has

stopped because an error has occurred while reading or writing data which
the drive cannot correct.”

A media error occurred during write or read

operation on the tape drive. Review the troubleshooting procedures

to ensure that the proper SCSI cabling and termination practices are

being followed. Restart the backup if any changes are made to the

SCSI cabling or termination or if any cables or terminator are

unplugged then re-plugged.
This message may also be seen with,

“The tape is from a faulty batch or

the tape drive is faulty.” or “The tape is damaged or the drive is faulty. Call the
tape drive supplier helpline.”

If either of these messages also appears, use

a good tape to test the drive. If the problem persists, call the tape

drive supplier helpline.

2

Remove the data tape and insert a cleaning cartridge. After the

cleaning cartridge ejects reinsert the data tape and restart the backup.

If the backup succeeds, the problem is resolved.

3

If the backup fails, try to isolate the tape media vs. tape drive. Use

diagnostic software to perform a write/read test of 4GB of data. The

current data on the tape

WILL BE OVERWRITTEN AND ALL

PREVIOUSLY WRITTEN DATA ON THE TAPE WILL BE DESTROYED.

Use a second tape for the diagnostic test. If

the diagnostic test passes

on the second tape, use the tape for the backup process and remove

the first tape from the backup process.

4

If the diagnostic test fails on the second tape, insert a cleaning tape

into the drive and repeat the diagnostic write/read test. If the

diagnostic test passes on the second tape, the problem is resolved.

5

If the diagnostic test fails on the second tape, the tape drive may be

bad. Use the diagnostic software to perform a write/read test on the

first data tape. The current data on the tape

WILL BE OVERWRITTEN.

ALL PREVIOUSLY WRITTEN DATA ON THE TAPE WILL BE
DESTROYED

. If the diagnostic test passes on the first tape, the

problem is resolved. If the diagnostic fails on the first tape, the tape is

bad and should not be used any longer.

6

If a second data tape is not available to test with the diagnostic

software, but a cleaning tape is available, insert the cleaning tape.

Remove the cleaning tape after the cleaning tape ejects and restart the

backup. If backup is successful, the tape drive and tape are

satisfactory.