Dsp-3 hardware support troubleshooting guide – QSC Audio DSP0002 User Manual

Page 2

Advertising
background image

2

DSP0002

Figure 1: COM port settings for

D S P - 3

Try plugging

DPX-1 into a

different outlet

or measure

output voltage

of DPX-1 for

15 volts.

Does DSP-3 have

power (blue LED)?

No

Is the DPX-1

power supply

being used?

No

Is the amplifier a

CX, DCA or PL2?

No

Was amplifier

manufactured after

August 1999?

Yes

The DSP-3

requires the

use of an

external power

supply with all

other

amplifiers.

No

CX, DCA, PL2

amps made prior

to 8/99 do not

provide

adequate power.

Use DPX-1 or

send amp to

QSC Technical

Services for

modification.

Yes

Is a DPX-2

DataPort

cable being

used?

Yes

No

A 4 channel CX

or DCA

amplifier

requires two

DataPort

cables, one

from each pair

of channels to

each DSP-3.

The fuse in the amplifier may

have blown. Check voltage

across pin 9 & 6 of DataPort

connector on amp for 15V

power. Use DPX-1 or return

amp to QSC for repair.

Yes

Yes

START

Does DSP-3 go

online?

Yes

No

DSP-3s manufactured before

7/99, or DSP-3s that have the

word ’DATA PORT’ printed

between the RS-232 and

DataPort connectors on the

front label use a NULL MODEM

cable. In all other cases USE a

S T R A I G H T T H R O U G H

SERIAL cable. If in doubt, try

the opposite cable of what is

being used.

Does the DSP-3 go

off-line periodically?

Is the correct

COM port
selected?

No

Select the

correct COM

port in the

Tools>Options

> D S P m e n u .

Yes

No

See DSP-3

Signal Manager

Software Support

Troubleshooting

Guide.

DSP-3 Hardware Support Troubleshooting

Guide

The operating

system has not

been qualified

for use with

Signal Manager.

Signal Manager
may or may not

work with
operating

systems that

have not been

qualified.

Which operating system

is being used; is it: Windows 95

4.01.0970B B or OSR2, Windows

98, or Windows NT 4.0 w/service

pack 5 or later?

No

Yes

Check COM port

settings. See

Figure 1.

Is the DSP-3

connected to the

computer using the

correct cable?

Yes

No

Yes

Are there any

applications running

that use the same

COM port (ex. hyper

terminal)?

Yes

No

Reboot computer

and operate

Signal Manager

without other

applications

active.

Return DSP-3 to

QSC for repair.

Failed

No

Advertising