Installing the Fireplace

Step 1. Locating the Fireplace

The diagram below shows space and clearance require-
ments for locating a fireplace within a room.

Figure 4A. Fireplace Dimensions and Locations

Clearance Requirements
The top, back, and sides of the fireplace are defined by
stand-offs. The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch (25 mm).
The metal ends of the fireplace may NOT be recessed into
combustible construction.

Note: Refer to Figure 4B for dimensions and appliance
locations if installing a QV-PIER-HV unit with a Catalina
shelf and/or marble package
.

Note: Refer to the Catalina installation instruction
included with kit for assembly and installation.

Figure 4B.

50-1/2 in.

34-1/2 in.

7 in.

47-1/2 in.

45-1/4 in.

13/16 in.

Marble sizes (inches):
Header .................................. 26 x 8
Side headers .................. 45-1/2 x 8
Legs ................................ 33-1/2 x 7

Í

45 -1/4 in.
(1149mm)

FINISHED

WALL

Fireplace Locations/Dimensions with

Catalina Shelf/Marble Package ONLY

О

О

Note: This location diagram MUST be followed when in-
stalling a QV-Pier-HV with a Catalina shelf/marble package
since the fireplace is installed further from finished wall.

36"

GLASS

GLASS

36"

GLASS

GLASS

GLASS

36"

36"

36"

QV-PIER-HV-IPI

TOP VIEW

QV-ST-HV-IPI

TOP VIEW