Section 2:

Installation- Connections

REAR PANEL- PAGE, RELAY & MONITOR CONNECTIONS

20

CONNECTING THE RLY OUT

The

RLY OUT connector provides access to the internal relay’s

contacts for remotely controlling an external low voltage device

or circuit. This internal relay is rated for 70V (DC or ACrms), 250

mA (switched) and is isolated from ground. There is one common

terminal, one normally-closed contact terminal and one nor-

mally-open contact terminal. These are labeled as

C, NC and NO

on the rear panel. When the relay is not energized, the

C terminal

is connected to the

NC terminal and the NO terminal is not

connected; when the relay is energized the

C to NC connection

is opened and the

C to NO connection is closed.

CONNECTING PAGE INPUT

The

PAGE input connections are the same as the AUDIO INPUT

connections. Please refer to the previous page for connector

pinout.

CONNECTING THE RLY/TRG IN

The

RLY/TRG IN connector is a two-pin terminal block connec-

tor. When using this input for a switch-closure (or opening)

event, the two terminals should be connected to the switch

contacts directly. This type of event detection can be used with

relay contacts as well.

If used with a logic-type device, the low-end of the logic

connection should be connected to the minus () terminal and

the active-end should be connected to the plus (+) terminal.

This input is compatible with TTL & CMOS logic family de-

vices. For the defined limits of input to this connector , please

refer to the specification section.

CONNECTING THE MONITOR CHAIN IN/OUT

The

MONITOR CHAIN connector is a 5-pin terminal block con-

nector. The center pin is the shield connection for

both the input

and output of the monitor chain. Note also that the positive

terminal of the input and output connections are on the outer

pins of this connector.

ATTENTION!

DO NOT CONNECT VOLTAGES EXCEEDING 70 VOLTS (DC or AC rms) TO THE RLY OUT CONNECTOR!

DAMAGE TO THE CM16a COULD RESULT OR CREATE HAZARDOUS OPERATING CONDITIONS!

If there is a need to switch

higher voltage or current levels with the CM16a, contact Technical Services for suggested solutions.

TIP- This input can be used to switch between

stand-alone preset operating modes without the

need of a computer. Setup for this feature is avail-

able through RS-232 or Telnet communications.