Toastmaster MBT240 User Manual

Page 5

Advertising
background image

5

2. Check that the appropriate receptacle is available

for the power cord plug.

3. Insert the power cord plug into its receptacle.

4. If required by national or local codes, connect an

equipotential ground wire to the lug next to the
symbol (shown in Figure 3). The equipotential
ground connection must meet all applicable na-
tional and local code requirements.

Checking the Installation

1. Check that the toaster is properly connected to

the electrical power supply.

2. Switch the circuit breaker/fused disconnect to the

ON (“I”) position.

3. Switch the

switch to the ON (“I”) position. The

display will flash

as the toaster pre-heats.

4. Allow the toaster to pre-heat for 15 minutes, until

appears in the display.

CAUTION - HOT SURFACES

USE CAUTION TO AVOID INJURY.

5. Look inside the toasting chamber and visually

check that the heating elements are heating and

glowing red.

6. Push and hold the

key for 2 seconds.

7. Push the

key.

8. Check that the digital timer begins counting down.
9. Wait for the preset time to elapse. The control

should sound an alarm as follows:

•

The control will beep 5 times at 1-second intervals.

•

Next, the control will beep very rapidly for another

5 seconds.

•

Next, the control will sound a steady tone.

10. Press the

key. The timer will reset, and the

steady tone will shut off.

11. Switch the

switch to the OFF (“O”) position.

The fan will remain in operation to allow the toaster
to cool.

12. After the fan stops, switch the circuit breaker/fused

disconnect to the OFF (“O”) position.

Electrical Connection

IMPORTANT

•

An electrical schematic for the toaster is provided

at the back of this Manual.

•

The electrical connection to the toaster requires a

circuit breaker/fused disconnect. Consult appli-

cable national and local code requirements to de-

termine the rating of the breaker/disconnect. Elec-

trical specifications are listed on the toaster’s se-

rial plate and in the Specifications section of this

Manual.

•

The toaster’s power cord and plug provide an

electrical ground connection. A separate

equipotential ground connection must also be

made if required by national or local codes. The

location of the equipotential ground lug is shown

in Figure 3.

•

Consult all applicable national and local codes for

further electrical connection requirements.

1. Before proceeding with the electrical connection,

check that the electrical supply matches the

toaster’s requirements. Refer to the serial plate

and to the Specifications section of this Manual.

WARNING
ENSURE THAT BOTH THE CIRCUIT

BREAKER/FUSED DISCONNECT AND THE
SWITCH ARE IN THE “O” (OFF) POSITION BE-
FORE PROCEEDING.

WARNING

ENSURE THAT ANY PACKING MATE-

RIAL RESIDUE HAS BEEN REMOVED FROM

INSIDE THE TOASTING CHAMBER.

Figure 3 - Equipotential Ground Connection

Equipotential ground

lug and symbol

Advertising