Gga as s c co on nn ne ec ct tiio on n, Bbu ur rn ne er r a ad djju us st tm me en nt t – Viking TruSearTM User Manual

Page 3

Advertising
background image

3

G

GA

AS

S C

CO

ON

NN

NE

EC

CT

TIIO

ON

N

Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate

agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-
off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or
in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1. IIn

n C

Caan

naad

daa:: Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation

Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type
and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.

The gas burner and its individual shut-off valve must be disconnected from the gas supply piping system

during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The unit must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that
system at test pressures equal to or less than 1/2 psi (3.5 kPa).

B

BA

AS

SIIC

C S

SP

PE

EC

CIIF

FIIC

CA

AT

TIIO

ON

NS

S

D

De

essccrriip

pttiio

on

n

V

VG

GIIB

B1

15

51

1T

T

V

VG

GIIB

B2

24

42

2T

T

Overall Width

15-5/16” (38.9 cm)

26 1/4” (66.7 cm)

Overall Depth

To end of landing ledge

31-9/16” (80.2 cm)

To end of knobs

32-5/8” (82.9 cm)

Overall Height

10 1/2” (26.3 cm)

Cutout Width

14” (35.6 cm)

24 3/4” (62.9 cm)

Cutout Depth

27-1/2” (69.9 cm)

Cutout Height

10-1/4” (26.0 cm)

Gas

Natural:

standard residential 1/2” (1.3 cm) ID gas service line.

Requirements

LP/Propane:

equipped with high capacity hose/regulator assembly for
connection to standard 5gal, 20 lb. LP/Propane gas cylinder
with Type 1, QCC-1 connection or standard residential 1/2”
(1.3 cm) ID gas service line.

Infrared Burner

21,500 BTU Nat./20,000 BTU LP

Rating

(6.3 kW Nat./5.9 kW LP)

Approximate Shipping

55 lbs. (24.8 kg)

160 lbs. (72.0 kg)

Weight

F

FLLA

AM

ME

E H

HE

EIIG

GH

HT

T

T

Trru

uS

Se

eaarr B

BU

UR

RN

NE

ER

R

1/4”

(.64 cm)

B

BU

UR

RN

NE

ER

R A

AD

DJJU

US

ST

TM

ME

EN

NT

T

Orifice

There is no burner adjustment for the infrared burner. Once heated, the flames should glow a bright red color.

Advertising