TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Residues from manufacturing

processes

1. Turning control knob to HI po-

sition when burner is cold

2. Air in gas line

3. Air passageways on fireplace

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from fur-

niture polish, wax, carpet
cleaners, etc. may turn into
white powder residue

1. Metal expanding while heating

or contracting while cooling

REMEDY

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO po-

sition and let warm up for a
minute

2. Operate burner until air is re-

moved from line. Have gas line
checked by local propane/LP
gas company

3. Observe minimum installation

clearances (see pages 9
through 12)

4. Clean burner (see Cleaning

and Maintenance, page 22) or
replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet
cleaners, or similar products

1. This is common with most fire-

places. If noise is excessive,
contact qualified service person

OBSERVED PROBLEM

Slight smoke or odor during ini-
tial operation

Fireplace produces a whistling
noise when burner is lit

White powder residue forming
within burner box or on adja-
cent walls or furniture

Fireplace produces a clicking/
ticking noise just after burner is
lit or shut off