W IRE YO UR SPA PER ONE OF THE DIAG RAMS MOST SIMILAR TO YO UR HOUSE PA NE L

ALL WIRES FEEDING THE SPA ARE TO BE THE SAME GAUGE. GROUND WIRES ARE TO
BE INSULATED AS WELL. WHEN USING A GROUND ROD, THE GROUND WIRE TO THE
ROD SHOULD BE #6 BARE COPPER.

ALL SPAS REQUIRE THE USE OF AN ISOLATED GFCI PROTECTED CIRCUIT. THE
INSTALLATION OF A DISCONNECT IS REQUIRED NO MORE THAN TEN (10) VISUAL
FEET FROM THE SPA AND NOT LESS THAN FIVE (5) FEET.

THIS REQUIREMENT IS TO ASSURE THAT WHEN POWER IS DISCONNECTED FROM THE
SPA, POWER CAN NOT BE INADVERTENTLY TURNED BACK ON.

EL E CT RICAL RE QUIREMEN TS AND INSTA L LAT ION

S E PA RATE NE U T RAL & SO L ID

G R O UND