S3

12

11

10

9

S2

8

7

6

5

S1

4

3

2

1

ON OFF

Rear View of the SQRG-12

2. Wiring Table for the TMS-6X

ROW 1

Loop/Ground Start

C.O. Lines

1T

1R

2T

2R

3T

3R

4T

4R

5T

5R

6T

6R

* Earth Ground

ROW 2

TMS-6X

L1, G
L1, R

L2, BK

L2, Y

L3, W

L3, BL

L4, G
L4, R

L5, BK

L5, Y

L6, W

L6, BL

ROW 3

SQRG-12

Pin, Color

26, W/BL

1, BL/W

27, W/O

2, O/W

28, W/G

3, G/W

29, W/BN

4, BN/W

30, W/S

5, S/W

31, R/BL

6, BL/R
50, V/S

ROW 4

Open

ROW 5

SQRG-12

Pin, Color

38, BK/G
13, G/BK

39, BK/BN
14, BN/BK

40, BK/S
15, S/BK

41, Y/BL
16, BL/Y

42, Y/O
17, O/Y
43, Y/G
18, G/Y

ROW 6

Loop/Ground Start

C.O. Lines

1T

1R

2T

2R

3T

3R

4T

4R

5T

5R

6T

6R

Note: For proper ground
start operation, DIP switches
1-12 must be set to OFF as
shown above.

* Note: Earth Ground is only required in ground start applications.

Notes: If the PABX does not recognize lines on the TMS-6X as busy and call crashing is observed, set up those lines as “incoming only trunks” on the PABX. If those lines
must be used for inbound and outbound calls, you must use the special software TMX-PRAL. Contact Viking product support at (715) 386-8666 for more information. Do not
install bridging clips on any connections which connect the two halves of the punch down terminal block. Bridge clips should only be installed as a method of bypassing equip-
ment. In order for the SQRG-12 to work properly, the four-wire modular jack must be installed between the TMS CONTROL LINE on the SQRG-12 and the SQRG jack on the
TMS-6X or TMS-12A.

RJ21X Male Jack

(not included)

13.8V AC

Adapter

(included)

Siemans

# 566B3-50

Marconi

# R66B3-50

1-12 C.O. Lines

Punchdown

Terminal

Block with

Split Center

(not included)

(V/S)
Earth Ground

SEQUENTIAL RING

GENERATOR

VIKING ELECTRONICS INC. HUDSON, WI 54016

VIKING

©

MODEL SQRG-12

POWER

13.8V AC

1.25A MAX

RESET

TMS

CONTROL LINE

1 2 3 4

ON

1 2 3 4

RJ21X

J2

RJ21X

J2

Trunk Inputs

of PABX/KSU

Note: Earth ground is required
in ground start applications.

Ground Start or
Ring All Lines

Loop Start

1 2 3 4

ON

ON

OFF

DIP

Switches

Rear View of the TMS-12A

MUSIC

Viking Electronics, Inc.

Hudson, WI 54016

POWER

13.8VAC

INPUTS / OUTPUTS

WARBLE
VOLUME

SQRG-12

TMS-RDMA

TMS-RDMA

ON

9 10 11 12

B. Installing the SQRG-12 with the TMS-12A

1. Wiring

S3

12

11

10

9

S2

8

7

6

5

S1

4

3

2

1

ON OFF

Rear View of the SQRG-12

2. Wiring Table for the TMS-12A

ROW 1

Loop/Ground Start

C.O. Lines

1T

1R

2T

2R

3T

3R

4T

4R

5T

5R

6T

6R

7T

7R

8T

8R

9T

9R

10T

10R

11T

11R
12T

12R

* Earth Ground

ROW 2

TMS-12A

Pin, Color

26, W/BL

1, BL/W

27, W/O

2, O/W

28, W/G

3, G/W

29, W/BN

4, BN/W

30, W/S

5, S/W

31, R/BL

6, BL/R

32, R/O

7, O/R

33, R/G

8, G/R

34, R/BN

9, BN/R

35, R/S
10, S/R

36, BK/BL
11, BL/BK

37, BK/O
12, O/BK
44, Y/BN

ROW 3

SQRG-12

Pin, Color

26, W/BL

1, BL/W

27, W/O

2, O/W

28, W/G

3, G/W

29, W/BN

4, BN/W

30, W/S

5, S/W

31, R/BL

6, BL/R

32, R/O

7, O/R

33, R/G

8, G/R

34, R/BN

9, BN/R

35, R/S
10, S/R

36, BK/BL
11, BL/BK

37, BK/O
12, O/BK

50, V/S

ROW 4

Open

ROW 5

SQRG-12

Pin, Color

38, BK/G
13, G/BK

39, BK/BN
14, BN/BK

40, BK/S
15, S/BK

41, Y/BL
16, BL/Y

42, Y/O
17, O/Y
43, Y/G
18, G/Y

44, Y/BN
19, BN/Y

45, Y/S
20, S/Y

46, V/BL
21, BL/V

47, V/O
22, O/V
48, V/G
23, G/V

49, V/BN
24, BN/V

ROW 6

Loop/Ground Start

C.O. Lines

1T

1R

2T

2R

3T

3R

4T

4R

5T

5R

6T

6R

7T

7R

8T

8R

9T

9R

10T

10R

11T

11R
12T

12R

Note: For proper ground
start operation, DIP switches
1-12 must be set to OFF as
shown above.

* Note: Earth Ground is only required in ground
start or master / slave applications.

DIP Switch

2
3

11

Position

UP

DOWN

UP

DIP Switch

2
3

11

Position

DOWN

UP
UP

Loop Start TMS-12A DIP Switches

Ground Start TMS-12A DIP Switches

Advertising