Query status of the digital input – Vivotek PZ6122 User Manual

Page 83

Advertising
background image




- 79 -

www.vivotek.com

T: 886-2-82455282

F: 886-2-82455532



Where state is H, L. H means NC (normal close) connected with COMMON and L means
NO (normal open) connected with COMMON. The number of DO dependents on the
server type.

parameter Value

description
H – NC connected with COMMON

do<num>

<state>

L – NO connected with COMMON

return

<return page>

Redirect to the page <return page> after the
parameter is assigned. The <return page> can be
a full URL path or relative path according the the
current path. If you omit this parameter, it will
redirect to an empty page.


Example: Drive the digital output 1 to high and redirect to an empty page

http://myserver/cgi-bin/setdo.cgi?do1=H

Query Status of the Digital Input

Note: This request requires the privilege of I/O access control.
Method: GET/POST

Syntax:
http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4]

If no parameter is specified, all the status of digital input will be returned.

Return:
HTTP/1.0 200 OK\r\n
Content-Type: image/jpeg\r\n
Content-Length: <length>\r\n
\r\n