Generally speaking, there are two rules to follow when connecting equipment outputs
to the inputs of other equipment.

1. Properly match the impedances of the outputs and inputs.

2. Connect low impedance outputs to high impedance inputs.

It goes without saying that not only input and output impedance matching but also
level matching should be taken into consideration. Each input channel of the MCX-

106 is provided with an input TRIM control, so the usable signal level range is very

wide. Input impedances and levels are shown in the following table.

*Sensitivity is the level required to produce a program out level of +4dBm.
*0dBm is referenced to 0.775V RMS.

All XLR Type connectors are electronically balanced (transformer less). Phone jack is
unbalanced.

If the line going from one piece of equipment to another is long (more than 5m), we
recommend that balanced outputs be connected to balanced inputs.

As is described in the beginning of the Operating Instructions Manual, the connectors
of the MCX-106 are wired as follows: Pin 1 is ground (shield). Pin 2 is cold (low,
minus). Pin 3 is hot (high, plus).

INPUT SPECIFICATIONS

CONNECTION

INPUT

ACTUAL
LOAD
IMPEDANCE

FOR USE

WITH
NOMINAL

TRIM
POSI-
TION

SENSITIVITY
(PGM OUTPUT
LEVEL +4dB)

MAX BEFORE

CLIP INPUT
LEVEL

CONNECTOR

CH6

AUX (L & R)

EFF/RET

GEQ

PWR

BUSS LINK

(PGM, FB, EFF)

LOW Z

HIGH Z

——

——

——

——

——

10

0

10

0

-55dBm (1.38mV)

-16dBm (123mV)

-35dBm (13.8mV)

+4dBm (1.23mV)

-34dBm (15mV)

+1.7dB (0.94V)

-14dBm (150mV)

+20dB (7.75V)

XLR TYPE NC3F

PHONE JACK

-l0dBm (245mV)

+8dBm (1.9V)

PHONE JACK

RCA PIN J A C K

-20dBm (77.5mV)

+4dBm (1.23V)

+4dBm (1.23V)

+4dBm (1.23V)

-2dBm (0.61V)

PHONE JACK

PHONE JACK

PHONE JACK

PHONE JACK

+20 dBm (7.75V)

OPEN

MICRO-
PHONES

LOWER IMP
LINES

LOWER IMP,
LINES

LOWER IMP,
LINES

LOWER IMP,
LINES

LOWER IMP
LINES