Owner’s manual, Troubleshooting, Continued – Vanguard Heating VN1800TB User Manual

Page 15

Advertising
background image

15

104820

OWNER’S MANUAL

OBSERVED PROBLEM

When ignitor button is pressed in, there is a
spark at ODS/pilot but no ignition

Burner(s) does not light after ODS/pilot is lit

Delayed ignition of burner(s)

Burner backfiring during combustion

Burner plaque(s) does not glow

Slight smoke or odor during initial operation

Heater produces a clicking/ticking noise
just after burner is lit or shut off

White powder residue forming within burner
box or on adjacent walls or furniture

TROUBLESHOOTING

Continued

REMEDY

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Fully open equipment shutoff valve
4. Hand tighten until snug, then tighten

1/4 turn more

5. A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 13) or replace ODS/
pilot assembly

6. Replace thermocouple
7. Replace control valve
8. Wait one minute for safety interlock sys-

tem to reset. Repeat ignition operation

1. Clean burner orifice(s) (see Cleaning

and Maintenance, page 13) or replace
burner orifice(s)

2. Replace burner orifice(s)
3. Contact local natural gas company

1. Contact local natural gas company
2. Clean burner orifice(s) (see Cleaning

and Maintenance, page 13) or replace
burner orifice(s)

1. Clean burner orifice(s) (see Cleaning

and Maintenance, page 13) or replace
burner orifice(s)

2. Replace burner
3. Replace gas regulator

1. Replace burner
2. Contact local natural gas company
3. Turn control knob until it locks at de-

sired setting

1. Problem will stop after a few hours of

operation

1. This is common with most heaters. If

noise is excessive, contact qualified ser-
vice person

1. Turn heater off when using furniture

polish, wax, carpet cleaners, or similar
products

POSSIBLE CAUSE

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Thermocouple connection loose at con-

trol valve

5. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

6. Thermocouple damaged
7. Control valve damaged
8. Safety interlock system has been trig-

gered (thermostat models only)

1. Burner orifice(s) is clogged

2. Burner orifice(s) diameter is too small
3. Inlet gas pressure is too low

1. Manifold pressure is too low
2. Burner orifice(s) is clogged

1. Burner orifice(s) is clogged or damaged

2. Burner damaged
3. Gas regulator defective

1. Plaque damaged
2. Inlet gas pressure is too low
3. Control knob set between locked

positions

1. Residues from manufacturing processes

1. Metal expanding while heating or con-

tracting while cooling

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue

Continued