Cooking, Installation requirements, Utility – Viking DECU165-5B 36"W User Manual

Page 4: Access requirements

Advertising
background image

Cutout opening

28-5/8”

(72.7 cm) min.

to

29-7/8”

(75.9 cm) max.

27”

(68.6 cm)

1-1/16”
(2.7 cm)

1-1/16”
(2.7 cm) 2-1/4”

(5.7 cm)

19-3/4”

(50.2 cm) min.

to

20-1/8”

(51.1 cm) max.

20-5/8”

(52.4 cm)

29-1/8”

(73.9 cm)

Cutout opening

34-3/4”

(88.3 cm) min.

to

35-7/8”

(91.1 cm) max.

33”

(83.8 cm)

15/16”

(2.4 cm)

15/16”

(2.4 cm)

2-1/4”

(5.7 cm)

20-5/8”

(52.4 cm)

19-3/4”

(50.2 cm) min.

to

20-1/8”

(51.1 cm) max.

34-7/8”

(88.6 cm)

Cutout opening

42-7/8”

(108.9 cm) min.

to

44-1/8”

(112.1 cm) max.

42”

(106.7 cm)

7/16”

(1.1 cm)

7/16”

(1.1 cm)

2-1/4”

(5.7 cm)

20-5/8”

(52.4 cm)

19-3/4”

(50.2 cm) min.

to

20-1/8”

(51.1 cm) max.

42-7/8”

(108.9 cm)

30”W. Cutout

36”W. Cutout

30”W. Cutout
w/Downdraft

45”W. Cutout

36”W. Cutout
w/Downdraft

45”W. Cutout
w/Downdraft

DECU106-4B

DECU166-5B

DECU156-6B

Cutout width

28-5/8” (72.7 cm) min.

34-3/4” (88.3 cm) min.

42-7/8” (108.9 cm) min.

29-7/8” (75.9 cm) max.

35-7/8” (91.9 cm) max.

44-1/8” (112.1 cm) max.

Cutout height

3-1/8” (7.9 cm) min.

With conduit

4-1/8” (10.5 cm)

Cutout depth

19-3/4” (50.2 cm) min. to 20-1/8” (51.1 cm) max.

Surface burner rating

240V

208V

240V

208V

240V

208V

Right front

1,500 watts

1,125 watts

1,500 watts

1,125 watts

1,500 watts

1,125 watts

Right rear (dual element)

2,500/1,000 watts/1,875/750 watts

2,200/

1,650/

2,200/

1,650 watts

1,000 watts

562 watts

950 watts

Center right

N/A

N/A

1,200 watts

900 watts

Center (dual element)

N/A

2,500/

1,875/

N/A

1,000 watts

750 watts

Center left (dual element)

N/A

N/A

2,500/

1,875/

1,000 watts

750 watts

Left front

1,800 watts

1,350 watts

1,800 watts

1,350 watts

1,800 watts

1,350 watts

Bridge

800 watts

600 watts

800 watts

600 watts

800 watts

600 watts

Left rear

1,800 watts

1,350 watts

1,800 watts

1,350 watts

1,800 watts

1,350 watts

DECU106-4B

30”W. Four-Element

Cooktop

DECU166-5B

36”W. Five-Element

Cooktop

DECU156-6B

45”W. Six-Element

Cooktop

COOKING

Designer Built-In Electric Radiant

30”/36”/45”W. Glass Ceramic Cooktop

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M

1 - 8 8 8 - V I K I N G 1

R E V I S E D 5 / 1 1 / 1 1

© 2 0 1 1 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

UTILITY

REQUIREMENTS

GAS
• Not applicable

ELECTRICAL
• 4-foot (121.9 cm)

flexible conduit
included*

• 3-wire conduit with a

No. 10 ground wire

• 240 – 208/120 V/60 Hz
• Maximum amp

usage—(240V/208V)
o 4B—35.0/30.0
o 5B—44.0/34.0
o 6B—49.0/42.0

• Do not use an

extension cord with
this appliance.

PLUMBING
Not applicable

Installation Requirements

ACCESS REQUIREMENTS

Note: Before cutting countertop cutout, check the inside clearance available from the inside back wall to the proposed
placement of the cooktop. A minimum of 1-3/4” (4.4 cm) is required from the back wall of the cooktop to the inside wall of
the back cabinet. This may require a distance greater than the 0” minimum approved distance.

Advertising