Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.

VENTILATION
• Check with a qualified and

trained installer or local codes
for makeup air requirements, if
any.

• Max. duct run

o For 300 – 1,200 CFM—50’

(15.2 m)

o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for general

reference only; always use a
qualified and trained installer.

o Straight runs and gradual

turns are best; for example,
each 90” elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm) of
straight run.

• 7’ round duct for 300 – 600

CFM; 10’ for 900 – 1500 CFM
o Never use flexible duct; it

creates back pressure/air
turbulence and greatly
reduces performance.

GAS
Not applicable

ELECTRICAL
• Hardwire direct with two-wire

with ground

• 120 VAC/60 Hz
• Max. amp usage (rating

includes rec. ventilator kit
rating)

PLUMBING
Not applicable

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.

Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or
exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

VENTILATION

Built-In Classic Chimney Wall Hood—

Standard, w/Ledge, & Ledgeless

Installation Requirements

Model

Ventilator kits

Duct size

Max. amps

Interior

Exterior

Interior

Exterior

Interior

Exterior

DCWH3042

DIV300/DIV440

DEV900/DEV1200

7” (17.8 cm)

10” (25.4 cm)

1.7/3.2

6.6/3.9

DCWH3644

DIV300/DIV600*

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

1.7/3.9

6.6/3.9

DCWH4244

DIV600

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

3.9

6.6/3.

DCWH4844

DIV1200*

DEV1200/DEV1500**

10” (25.4 cm)

10” (25.4 cm)

7.3

4.3/5.1

DCWL3342

DIV300/DIV440

DEV900/DEV1200

7” (17.8 cm)

10” (25.4 cm)

1.7/3.2

6.6/3.9

DCWL3944

DIV300/DIV600*

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

1.7/3.9

6.6/3.9

DCWL4544

DIV600

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

3.9

6.6/3.9

DCWL5144

DIV1200

DEV1200/DEV1500**

10” (25.4 cm)

10” (25.4 cm)

7.3

4.3/5.1

DCWN3042

DIV300/DIV440

DEV900/DEV1200

7” (17.8 cm)

10” (25.4 cm)

1.7/3.2

6.6/3.9

DCWN3644

DIV300/DIV600*

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

1.7/3.9

6.6/3.9

DCWN4244

DIV600

DEV900/DEV1200*

7” (17.8 cm)

10” (25.4 cm)

3.9

6.6/3.9

DCWN4844

DIV1200*

DEV1200/DEV1500**

10” (25.4 cm)

10” (25.4 cm)

7.3

4.3/5.1

Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly