Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.

DUCTING
• 450 CFM interior (blower

included)

• Check with a qualified and

trained installer for local codes
and makeup air requirements,
if any.

• Max. duct run length—50’

(152.4 m)
o Duct run length is for general

reference only; for longer
duct runs, increase duct size
and contact a qualified and
trained installer.

o Straight runs and gradual

turns are best; for example,
each 90” elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm) of
straight run.

• 6” round duct

o Never use flexible duct; it

creates back pressure/air
turbulence and greatly
reduces performance.

GAS
Not applicable

ELECTRICAL
• Hardwire direct with two-wire

with ground

• 120 VAC/60 Hz
• Max. amp usage—3.13

PLUMBING
Not applicable

VENTILATION

Built-In Classic Chimney Glass Wall Hood

Installation Requirements

Model

Interior Ventilator Kits

Interior Duct Size

Interior Max. Amps

DGWH3646

450 CFM Standard

6” (15.2 cm)

3.13

Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly
overstated.