VENTILATION

Built-In Custom Ventilator Systems

Proper installation/ ducting is
extremely important to ensure
maximum performance. Use a qualified
and trained installer.

DUCTING
• Check with a qualified and

trained installer or local codes
for makeup air requirements, if
any.

• Max. duct run length

o For 300 – 1,200 CFM—

50’ (152.4 m)

o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for

general reference only;
always use a qualified and
trained installer.

o Straight runs and gradual

turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm)
of straight run.

• 7” (17.8 cm) round duct for

300 – 600 CFM; 10” for 900 –
1500 CFM
o Never use flexible duct; it

creates back pressure/air
turbulence and greatly
reduces performance.

GAS
Not applicable

ELECTRICAL
• Hardwire direct with two-wire

ground

• 120 VAC/60 Hz
• Max. amp usage (rating

includes recommended
ventilator kit rating)—see
Installation Requirements
table

PLUMBING
Not applicable

Installation Requirements

Model

Ventilator Kits

Duct Size

Max. Amps

Interior

Exterior

Interior

Exterior

Interior

Exterior

VBCV3038

VIV300/600/1200*

VEV900/1200*

7” (17.8 cm)/

10” (25.4 cm)

5.0/6.2/8.7

8.7/6.1

10” (25.4 cm)

VBCV3638

VIV300/600/1200*

VEV900/1200*

7” (17.8 cm)/

10” (25.4 cm)

5.0/6.2/8.7

8.7/6.1

10” (25.4 cm)

VBCV4238

VIV600/1200*

VEV900/1200*

7” (17.8 cm)/

10” (25.4 cm)

6.2/8.7

8.7/6.1

10” (25.4 cm)

VBCV4838

VIV1200*

VEV1200*/1500

10” (25.4 cm)

10” (25.4 cm)

11.1

8.4/9.1

VBCV5438

VIV1200*

VEV1200*/1500

10” (25.4 cm)

10” (25.4 cm)

11.1

8.4/9.1

VBCV6038

VIV1200*

VEV1200*/1500

10” (25.4 cm)

10” (25.4 cm)

11.5

8.8/9.5

VBCV6638

VIV1200*

VEV1200*/1500

10” (25.4 cm)

10” (25.4 cm)

11.5

8.8/9.5

VICV3698

VIV600/VIV1200*

VEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

4.9/7.4

7.4/4.7

VICV4298

VIV600/1200*

VEV900/1200*/1500

7” (17.8 cm)

10” (25.4 cm)

4.9

7.4/4.8/5.4

VICV5498

VIV1200*

VEV1200*/1500

10” (25.4 cm)

10” (25.4 cm)

8.2

5.6/6.2

VICV6698

VIV1200*

VEV1200*/1500

10” (25.4 cm)

10” (25.4 cm)

9.0

6.3/7.1

DBCV3082

DIV300/440

DEV900**/1200*

7” (17.8 cm)

10” (25.4 cm)

1.7/3.2

6.6/3.9

DBCV3682

DIV300/440

DEV900**/1200*

7” (17.8 cm)

10” (25.4 cm)

1.7/3.2

6.6/3.9

DBCV4282

DIV440

DEV900**/1200*

7” (17.8 cm)

10” (25.4 cm)

3.2

6.6/3.9

DBCV4882

DIV880

DEV1200/1500

10” (25.4 cm)

10” (25.4 cm)

5.6

4.3/5.1

DICV3632

DIV440

DEV900**/1200*

7” (17.8 cm)

10” (25.4 cm)

4.0

7.5/5.2

DICV4232

DIV440

DEV900**/1200/1500

7” (17.8 cm)

10” (25.4 cm)

4.0

7.5/5.2/6.0

DICV5432

DIV880

DEV1200/1500

10” (25.4 cm)

10” (25.4 cm)

6.4

5.2/6.0

*1200 CFM interior and exterior (if applicable) ventilator should be used with all outdoor approved models and when indoor models are installed over

ranges/rangetops with gas grill.

**Must use 8” duct from canopy to ceiling – trasition to 10” duct past duct cover.

Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.

UTILITY REQUIREMENTS