Figure 7-19 old hsdb switch settings, The repeater is now in normal operation mode, 7 switch (rnt) interface – Viking 242-2009-632 User Manual

Page 149: 1 repeater setup, 2 cim setup

Advertising
background image

ALIGNMENT AND TEST PROCEDURES

7-21

March 1999

Part No. 001-2009-600

2. Verify that the repeater is programmed for "Stand

Alone" mode in Setup Parameters-F4 (see Section
4.3.3).

3. The repeater is now in Normal Operation mode.

Verify by the MPC front panel indicators that no
HSDB alarms have occurred (Alarm Number 10)
see Table 1-2.

Old HSDB Test

1. Switch settings on the MPC for single-ended 5V

(old style) operation are shown in Figure 7-19.
S002 Sections 1-8 Off. S003 all sections On.

Figure 7-19 OLD HSDB SWITCH SETTINGS

2. Verify that the repeater is programmed for "Stand

Alone" mode in Setup Parameters-F4 (see Section
4.3.3).

3. The repeater is now in Normal Operation mode.

Verify by the MPC front panel indicators that no
HSDB alarms have occurred (Alarm Number 10)
see Table 1-2.

Handshake Test

1. Program an LTR, portable or mobile, for the follow-

ing parameters.

Home Repeater - Same as repeater number.
Home Channel - Same as repeater channel.
Area - Same as repeater’s area bit.
Encode ID - 1
Decode ID - 1

2. The repeater is now in Normal Operation mode.

3. Key the radio several times on the programmed Sys-

tem/Group. Access should occur every time.
(Proper Tx/Rx antenna connections are assumed.)

Alarm Test

1. The repeater is now in Normal Operation mode.

2. Verify by the MPC front panel indicators that no

alarms have occurred (see Table 1-2).

7.7 SWITCH (RNT) INTERFACE

7.7.1 REPEATER SETUP

1. Connect the repeater as shown in Figures 7-7, 7-20

and 7-21.

2. Adjust the repeater for the type of link used for com-

munication back to the CIM in the Switch. The
types of links used are:
Leased Lines (LL)
Direct Connection (DC)
Microwave (MW)
T1 Interfaces (T1)

3. Program the repeater for the specified parameters

using the Programmer.

NOTE: Assume all audio generators and voltmeters to
be unbalanced unless stated otherwise.

7.7.2 CIM SETUP

1. Adjust the CIM for the type of link used for commu-

nication back to the repeater. The types of links
used are:
Leased Lines (LL)
Direct Connection (DC)
Microwave (MW)
T1 Interfaces (T1)
Refer to the LTR-Net Switch, Setup and Alignment
manual, PN 001-3239-001, for more information on
the CIM alignment (see Figure 7-31).

2. Connect the link lines to the Switch and its associ-

ated CIM (see Figure 7-21).

ON

ON

S3

S2

2

1

8

7

6

5

4

3

2

1

4

3

Advertising