Cooking, Installation requirements – Viking DSCD130-4BSS User Manual

Page 4

Advertising
background image

2”

dia.

(5.1 cm)

3-1/8”

(7.9 cm)

2-1/2”

(6.4 cm)

1-7/8”

(4.8 cm)

29-1/4”

(79.3 cm)

24-7/8”

(63.2 cm)

Gas or electrical
connection in
this area

Gas connection
in this area

3-1/2”

(8.9 cm)

32”

(81.3 cm)

COOKING

Designer Freestanding Dual Fuel Self-Clean 30”W. Sealed

Burner Range

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M

1 - 8 8 8 - V I K I N G 1

R E V I S E D 8 / 2 6 / 1 0

© 2 0 1 0 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

UTILITY

REQUIREMENTS

GAS
• Shipped natural

gas standard;
field convert to
LP/propane with
optional accessory
kit or order as LP
by adding LP
after color code

• Accepts standard

residential 1/2” ID
gas service line

• Gas manifold

pressure

o Natural gas 5.0”

W.C.P.

o LP/Propane

10.0” W.C.P.

ELECTRICAL
• 240-208 VAC 60
Hz electrical
connection box on
product, connect
with locally supplied
3-wire, flexible cord
or “pigtail” rated 40
amp. 125-250 VAC
minimum. Cord
must be agency
approved for use
with household
electric ranges.

• Maximum amp

usage—
o 30”W. 4B—
240V - 25.4 amp
208V - 22.9 amp

PLUMBING
Not applicable

Installation Requirements

ACCESS REQUIREMENTS

Note: Ground plug and electrical wire toward the direction of the electrical outlet.

DSCD130-4B

Surface burner rating

Left front

16,000 BTU Nat. (4.7 kW)/15,500 BTU LP (4.5 kW)

Left rear

12,000 BTU Nat. (3.5 kW)/11,500 BTU LP (3.4 kW)

Center

Right rear

8,000 BTU Nat. (2.0 kW)/7,500 BTU LP (1.9 kW)

Right front

6,000 BTU Nat. (1.5 kW)/5,500 BTU LP (1.4 kW)

** Top of grates should be 3/8” (1.0 cm) above countertop.

DSCD130-4B

30”W. Four Burner Range

Advertising
This manual is related to the following products: