Electrical connection, Installation, Technical data – Zanussi ZBM 878 User Manual

Page 29

Advertising
background image

30

Electrical Connection

The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.

It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.

The switch must not break the yellow and green earth
cable at any point.

Important

After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 60

°

C above the ambient temperatu-

re.

Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should
these safety measures not be carried out.

DIMENSIONS

Height

580 mm.

OF RECESS

Width

560-570 mm.

Depth

550 mm.

DIMENSIONS

Height

320 mm.

OF THE

Width

420 mm.

OVEN CAVITY

Depth

390 mm.

Oven capacity

53.2 litres

Heating elements rating

Oven element

1.89 kW

Top element

0.834 kW

Bottom element

1.055 kW

Convection element

2.08 kW

Grill element

1.82 kW

Double Grill element

2.655 kW

Pizza Oven Function

3.135 kW

Convection Fan

30 W

Oven Light

15 W

Cooling Fan

25 W

Total Rating

3.200 kW

This oven must be installed by qualified
personnel
to the relevant British Standards.

Technical Data

The oven must be installed according to the
instructions supplied.

Installation

Connection

Min. size

Cable / flex Fuse

via

Cable/flex

type

• Cooker

6 mm

2

PVC/PVC

20 A

Control

twin and

Circuit

earth

For Uk use only

For Europe use only

Min. size Cable/flex

Cable / flex type

Fuse

2.5 mm

2

H05 RR-F

20 A

Advertising