Accusys StorConn GUI User Manual

Page 12

Advertising
background image

http://www.accusys.com.tw

11

User’s Manual


Configure Setup
Configure mail alert setting. The mail alert settings should be configured so that, in the event of
a RAID failure, the RAID administrator will be notified at once. The mail alert settings allow this
to be done via email, so the administrator can passively monitor RAID status from anywhere,
without having to keep monitoring StorConn.
The steps below will guide you to configure the mail alert settings:

1. Click Config.Setup. The System
Configuration Setup dialog box will open.

2. Enter the following values:
Mail Server:
Enter the host name of the mail server in your network or its FQDN (e.g.
accusys.com.tw). If no Mail Server information is added, the mail alert function will be disabled.
IP Address: Enter the IP address of the mail server in your network or its FQDN (Entries in the
top two fields should be identical)
Administrator’s Emails: Enter email addresses for two administrators.
Delay Time (Minute): If a RAID failure occurs, an alert email will be sent immediately to each
of the email addresses entered in the above field. Alert emails will continue to be sent until the
problem is resolved. The Email will notify events which are disk status (off line, fails, rebuilding,
rebuild OK, have bad sector, SMART warning) and RAID fails. Also enclosure events, fan fail,
temperature fail, battery abnormal (ACS-75170, ACS-75200, ACS-76130 and ACS-76200 only)
and power abnormal (ACS-78100 only)
Enter here the desired time lapse between successive emails (minimum = 1 minute)
Web Server Port: You can input any figure between 1 and 65535
3. Click Save to save the new configuration.

History log
View the history log. All malfunctions and events triggering an alert email are recorded in the
history log. Select the History Log menu can view the log of error message.