Appendix d: power consumption, Power consumption management – Acura Embedded AcuPanel 15 User Manual

Page 88

Advertising
background image

Appendix D: Power Consumption

Appendix D: Power Consumption

Power Consumption Management

Purpose

The purpose of the power consumption test is to verify the power dissipation

of the system and the load of the power supply.

Test Equipment

1. PROVA CM-07 AC/DC CLAMP METER

2. Burn-in test ver:2.0

Device Under Test

DUT: sys#1/

Test Procedure

1. Power up DUT and then boot Windows 7.

2. Enter the standby mode (HDD power down).

3. Measure the power consumption and record it.

4. Run the Burn-in test program to apply 100% full loading.

5. Measure the power consumption and record it.

AcuPanel 15

Full-Loading Mode

Total

Standby Mode

Total

+12V

3.2A

38.4W

0.75A

9W

+24V

1.65A

39.6W

0.41A

9.84W

+30V

1.26A

37.8W

0.36A

10.8W

83

Advertising