Enc 250, Scale tape installation – ACU-RITE ENC 250MS User Manual

Page 8

Advertising
background image

Acu-Rite Companies Inc.

ENC 250

MULTI-SECTION

• Before inserting the tape completely into the case, check

the tension value on the backside of the scale tape at the
anchor end. Check the value on the label attached to the
right end section, and verify that it is correct.

• The two M3 x 8mm Flat Head Socket Screws must be

removed from the scale anchor block. Continue pushing
the scale tape into the case until the anchor end is flush
with the left side of the case. Make sure that all the
scale tape retainer clips go into the T-slot.
If the scale
tape can not be inserted completely by pushing at one end,
the scale tensioner may be pulled along the case with a
small steel ruler from the bottom of the scale case.

• Place the Scale Tensioner into the tee slot on the left end

of the scale case.

• Retrieve the scale tape from the carton. The scale tape is

shipped in a protective plastic coil. Do not uncoil the tape.
It should be uncoiled as it is inserted into the case. The
tape must be kept free of fingerprints and contaminants.
It is best to wear clean cotton gloves when handling it. If
necessary, the scale tape may be cleaned with cotton cloth
soaked in alcohol or acetone.

• Hook the boss on the scale tensioner through the square

hole in the scale tape to capture the tape and slide the
scale tensioner into the scale case. Note – the gold
rulings on the scale tape must face into the scale
cavity.

Scale Tape Installation

Scale Tensioner

End view of

tee slot

Scale Tape

Anchor block

Retainer clip

End view of

tee slot

Tape tension value

0.XXX mm

• Apply a small amount of silicone grease – as a sealant - to

the two M3 x 8mm FHSS.

• Insert the screws through the scale case and thread into

the anchor block. Tighten fasteners completely.

• Draw a line onto the front of the scale case at a distance of

[0.65”] 16.5mm from the left end. Similarly draw a line
onto the front of the scale case at a distance of [2.46”]
62.5mm from the right end. These are the end-of-travel
marks. The ends of the reading head must not travel
beyond those lines.

• Find the center distance between the two lines and draw

another line onto the front of the scale case. This line
represents the center of travel. The reading head must be
mounted so that it is centered under this line when the
machine carriage is located at the center of its axis travel.

[2.46”] 62.5mm

Equal

Equal

[0.65”] 16.5mm

Left end of

travel mark

Center of

travel mark

Right end of

travel mark

• Insert a lip seal into the front keyhole slot (the one closest

to the scale tape) until it protrudes at least 1/2” [12mm]
from the far side. Lip seals must be installed with the
keying features opposing each other.

• Similarly, insert the rear lip seal. Make sure that the lip

seals are not under excessive tension in the case.
Normally, the lip seal can be pulled through completely
with a pair of needle-nose pliers.

Lip seal keying feature

7

This view shows lip seal orientation.

It is not required for them to be inter

locked during installation.

Advertising
This manual is related to the following products: