Veris Technologies pH Manager - Operating Instructions User Manual

Page 36

Advertising
background image

Pub.# OM17-MSP-pH

4-7

Towed Units

Raise sampling mechanism to full height. Begin depth adjustment process with shank in center
position (pin in one of two center holes). Install 2-

3“ (5-7.5 cm) of cylinder depth stops on main lift

cylinder. Lower implement into soil until main lift cylinder bottoms out against depth stops. Adjust
threaded top link to level unit.

Figures 10 a,b,c

Figure 11

Once unit is level, lower sampling mechanism completely, drive forward 10-

20’ (3-6 m) to create

soil core. To measure depth of soil core being collected, brush away soil from cutting shoe.
Measure from soil surface to top of cutting shoe. This is the depth of sampling. To increase
sampling depth, remove cylinder stops; to decrease sampling depth, add stops. Re-leveling unit
with adjustable top link may be required.

Figure 12

sampling depth
is measured
from top of
cutting shoe to
soil surface

begin with shank
in one of two
middle positions

begin with 2-

3”

(5-7.5 cm) of
depth stops

Adjust tractor or
implement top link to
level

Operate implement parallel to soil or
slightly

tipped (up to ½”) forward never allow

unit to tip backward --this will decrease shoe
penetration.

Advertising