Technical Data

KFD2-BR-Ex1.3PA.93

098

31

4_

EN

G.xm

l

2

003

-03-

1

3

Supply

Connection

Power Rail or terminals 59+, 60-, 58 FE

Rated voltage

20 ... 35 V DC

Ripple

≤ 10 %

Rated current

190 mA ... 430 mA

Fieldbus connection

Profibus PA

Connection

terminals 3, 18+; 2, 17-

Rated voltage

12,6 ... 13,4 V

Rated current

≤ 100 mA

Terminating impedance

100

Ω , integrated

Profibus DP

PROFIBUS with RS 485 transmission technique

Connection

terminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VP

Baudrate 93,75

kBit/s

Terminating impedance

with rotary switch (S1) switchable: 1 = on; 0 = off

Electrical isolation

Profibus PA/Profibus RS 485-Segment

safe electrical isolation acc. to EN 50020, voltage peak value 375 V

PROFIBUS DP/Supply

function insulation acc. to DIN EN 50178, rated insulation voltage 50 V

eff

PROFIBUS PA/Supply

safe electrical isolation acc. to EN 50020, voltage peak value 375 V

Standard conformity

Electrical isolation

EN 50178

Electromagnetic compatibility

NAMUR NE 21

Protection degree

IEC/EN 60529

Fieldbus standard

EN 50170/2

Climatic conditions

DIN IEC 721

Directive conformity

Electromagnetic compatibility

Directive 89/336/EG

EN 61326, EN 50081-2

Ambient conditions

Classification 3K3

Ambient temperature

-20 ... 60 °C (253 ... 333 K)

Storage temperature

-40 ... 85 °C (233 ... 358 K)

Relative humidity

< 75 %

Degree of soiling

max. 2, according to IEC 664

Mechanical specifications

Connection type

terminals

Core cross-section

up to 2.5 mm

2

Housing

100 mm x 115 mm x 107 mm

Protection degree

IP20

Mass 650

g

Mounting

DIN rail mounting

Data for application in conjunction with
hazardous areas

EC-Type Examination Certificate

PTB 99 ATEX 2142

Group, category, type of protection,
Temperature classification

¬ II (1) G D [EEx ia] IIC

Statement of conformity

TÜV 00 ATEX 1531X

Group, category, type of protection,
Temperature classification

¬ II 3 G EEx nA IIC T4

Supply

Safety maximum voltage U

m

40 V DC

Profibus PA

Voltage U

o

15

V

Current I

o

207,2 mA

Power

P

o

1,93

W

Safety maximum voltageU

m

60 V

Directive conformity

standards

Directive 94/9 EU

EN 50014, EN 50020, EN 50021