c. DMX512 Connection

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-

pin XLR input of the VDP1601RGLD10. Multiple VDP1601RGLD10s can be linked through serial linking. The linking
cable should be a two-core screened cable with XLR input and output connectors.

d. DMX512 Chain with Termination

A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator

prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120Ω resistor between pins 2 and 3, which is then plugged into

the XLR output socket of the last device in the chain.
Please see illustrations.

e. Start Address Selection

All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to “listen” to the DMX controller. Enter the correct

number and read it from the display located on the base of the VDP1601RGLD10.
You can use the same starting address for a whole group of devices or enter an individual one for every device.

When all devices have the same address, all the VDP1601RGLD10s will “listen” to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you

set different addresses, each device will “listen” to a separate channel number. Changing the settings of one channel
will only affect the device in question.

In the case of the 10-channel VDP1601RGLD10, you will have to set the start address of the first VDP1601RGLD10
to 1, the second VDP1601RGLD10 to 11 (1 + 10), the third to 21 (11 + 10) and so on.

7. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)

should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.

3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.

5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.

7. There are no user-serviceable parts apart from the fuse.
8. Contact your dealer for spare parts if necessary.

8. Technical Specifications

Power Supply

max. 230VAC / 50Hz

Power Consumption

15W

Fuse

F3A, 250VAC (5 x 20mm) (order code FF3N)

Dimensions

340 x 210 x 90mm

Total Weight

4kg

Max. Ambient Temperature

45°C

Max. Housing Temperature

90°C

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of