• Wait ± 3 minutes until the temperature is displayed on the weather station. Do not press any keys before

the weather station has received data.

• Mount both units (see “6. Mounting the Units”) at a distance where the weather station is still able to pick

up the signal from the sensor.
Every time the outdoor sensor is powered up (after e.g. a battery replacement), a random security code will
be transmitted. This code must be synchronized to the base station in order to receive weather data. The

station base must also be powered up when replacing the batteries in the outdoor sensor.
When the weather station is powered up, a short beep will sound and all LCD segments will light for 3
seconds before the station enters into the learning mode. After the learning mode the station will start DCF

radio-controlled time reception and RCC time reception for ± 10 minutes during which it will not be able to

receive any weather data. If the RCC signal cannot be found within 1 minute, the signal search will be

cancelled and will automatically resume every two hours until the signal is successfully captured. Regular RF
link will be established once the RCC reception routine is finished.
Do not press any key during the learning period (± 3 minutes). After both indoor and outdoor data is

displayed you can install the remote outdoor sensor and set the time (if no RCC reception is available). If
there is no temperature reading on the outdoor station make sure both units are within transmission range

or check the batteries. If you press a key before the weather station receives the temperature signal, take

out the batteries and reinstall them after ± 10 seconds.
Time and date are provided by a highly accurate atomic clock. Note that, whenever reception is possible, the

weather station will scan for the DCF radio signal and overwrite a manually set time and date.

6. Mounting the units

a. The Base Station

Place the base station onto a flat surface by deploying the foldable legs at

the back of the unit. The unit can also be wall-mounted. It is important to

check that the radio signal can be received before permanently mounting

both units.

b. The Outdoor Station

To achieve true temperature reading, avoid mounting the remote sensor in

direct sunlight. We recommend mounting the sensor on an outdoor north-
facing wall. Obstacles such as walls, concrete and large metal objects will

reduce the transmission range.

To wall-mount the sensor, fix the bracket on the wall using the three
screws. Fix the unit onto the bracket as shown.

7. Description of the LCD

a. Overview

Refer to the illustration on page 2 of this manual.

1 DST (Daylight Saving Time)

16 outdoor humidity

2 DCF77 radio signal

17 outdoor temperature and humidity HI / LO alarm

3 time

18 temperature scale

4 radio-controlled time icon

19 outdoor temperature

5 alarm on icon

20 general outdoor alarm

6 day of the week / time zone

21 weather forecast

7 date

22 weather tendency

8 indoor humidity

23 pressure HI alarm

9 indoor temperature and humidity HI / LO alarm 24 absolute or relative atmospheric pressure selection

10 indoor temperature

25 pressure LO alarm

11 temperature scale

26 atmospheric pressure with 24-hour history graph

12 indoor temperature and humidity alarm on

27 atmospheric pressure

13 outdoor sensor signal transmission

28 atmospheric pressure scale

14 MIN / MAX

29 atmospheric pressure alarm

15 dew point temperature

b. Weather icons

The four weather icons (sunny, partly cloudy, cloudy and rainy) represent the weather icons. These icons are

based upon change of atmospheric pressure.

sunny partly

cloudy

cloudy

rainy