6. Installation

Guidelines

A qualified technician should install and service this device.
The construction to which the device is attached should be able to

support 4 times the weight of the device for one hour without
deformation.

Never stand directly below the device when it is being mounted, removed

or serviced. Have a qualified technician check the device once a year and
once before you bring it into service.

Overhead mounting requires extensive experience: calculating workload

limits, determining the installation material to be used… Have the
material and the device itself checked regularly. Do not attempt to install
the device yourself if you lack these qualifications as improper installation

may result in serious injuries.

Do not fix the device to flammable surfaces.
This device is not suitable for dimming.

Distances

Keep the device at least 20 cm away from ceilings or walls.
Respect a minimum distance of 1 m between the device’s light output and

any illuminated surface.

Mounting the Lamp
1.
This luminaire does not have a built-in device to disconnect it from the

electric mains. Make sure to electrically isolate the luminaire before

installation or maintenance activities are performed.

2. Use the mounting bracket [4] to determine the location of the mounting

holes.

3. Drill the holes and secure the bracket using 2 screws and wall plugs.
4. Connect the power cable [5] to a suitable junction box [6] (not incl.).

Make sure the connection is properly earthed. Make sure there is no

strain on the cable; leave sufficient slack.
Warning: if the power cable is damaged, it must be replaced by the
manufacturer, his service agent, or a similar qualified person in order to
avoid any hazard.

5. To point the lamp in the desired direction: loosen the hinges [3] using a

6 mm Allen key.

6. Tilt the lamp in the desired angle and tighten the hinges.

7. Cleaning and Maintenance

This luminaire does not have a built-in device to disconnect it from the

electric mains. Make sure to electrically isolate the luminaire before
installation or maintenance activities are performed.

All screws should be tight and free of corrosion.