DATA SHEET


Parapet Wall Vent

“Duro-Last” and “EXCEPTIONAL” are registered marks owned by Duro-Last Roofing, Inc.

Revised 8/12/2012

Description:

The Parapet Wall Vent is engineered for maximum
ventilation with pre-punched slots on the bottom along
with louvered face.

Fabricated from 24-gauge vinyl-coated metal
and pre-finished Galvalume

®

14” wide and 10”

tall with a 6” Duro-Last

®

attached skirt.

Parapet vent provides 44.5 in

2

of net free area.

Parapet ventilation area for the attic area without
vapor retarder is 1 sf (ventilation)/150 sf of attic
area.

Parapet ventilation for new construction attic
area that provides a vapor retarder is 1 sf
(ventilation) / 300 sf of attic area. See the IBC
for ventilation requirements.

Contact Duro-Last or EXCEPTIONAL

®

Metals to

request a color chart, samples and information
regarding custom metals and finishes.

Energy Efficiency:

LEED

®

and ENERGY STAR

®

compliant; 100%

recyclable.

Installation:

1.

Install in accordance with Duro-Last detail
drawings #6010 and #6015.

2.

Any deviation from the requirements set forth in
the detail drawings must be pre-approved, in
writing, by the EXCEPTIONAL Metals Technical
Department.

Warranty:

Duro-Last offers a wide range of warranty coverage for
EXCEPTIONAL Metals products when used with the
Duro-Last roofing system, including paint and finish.


Technical Services:

Product samples, detail sheets, color chips, and color
chart are available for your submittal package. For
assistance with questions or submittals, contact your
local representative or call EXCEPTIONAL Metals.