Littelfuse LCP Fused Coordination PaneL User Manual

Lcp fused coordination panel, Pre-engineered solution datasheet, Selective coordination panel features/benefits

Advertising
background image

Pre-Engineered Solution Datasheet

Littelfuse.com

© 2013 Littelfuse POWR-GARD

®

Products

Rev: 011113

1 of 3

LCP Fused Coordination PaneL

Selective Coordination Panel

Features/Benefits

• Meets NEC

®

requirements

• Class CC and J fuse holders have built-in

open-circuit indication

• Fast-acting UL Listed fuses protect against short circuits
• Feed through/sub feed lugs and 84-circuit

configuration available

• Ground and neutral bars
• Copper bus standard

Advanced Design Options

• MLO, Main Circuit Breaker, or Main Fused Pullout device
• Fused Class T branch circuit pullout
• Spare fuse cabinet accessory (holds six spare fuses)
• TVSS overvoltage protection
• Any NEMA enclosure required
• High amperage sub-fed branch breakers (J60A)
• Unique Specifier Tool (see pg. 146) to easily identify panel

configurations from tens of thousands of options

Specifications

Voltage Ratings

120/208, 120/240, 277/480 VAC

Main Bus Rating

100 A - 400 A Standard

Conductor Terminals

6 AWG - 300 kcmil

UL Listed

UL 67 Panel boards and UL 50 Enclosures

Web Resources

Fuse Curves, sample requests, downloadable CAD
drawings and other technical information:
Littelfuse.com/lcp

Description

The Littelfuse

®

Coordination Panel provides a simple,

time-saving solution for circuits that require selective
coordination. This UL Listed product saves time and money,
and increases safety by minimizing system downtime.

Applications

• Elevators
• Hospitals
• Hotel and Entertainment Industry
• Amusement Parks and Stadiums

Code Requirements

Systems required by the NEC

®

to be selectively

coordinated include:

• Health Care Essential Electrical Systems (NEC 517.26)
• Elevators (NEC 620.62)
• Emergency Systems (NEC 700.27)
• Legally Required Standby Systems (NEC

701.18)

• Critical Operations Power Systems (NEC 708.54)

† Fuses quoted separately to meet panel specifications. Coordination for breakers >60 A depends on upstream and

downstream devices. More specialized configurations are also available. Contact factory for more information.

Note: The Littelfuse LPS, LPMP and LCP products are custom
designed products that fall outside standard specifications.

Custom Options (select one from each column)

number

oF

CirCuits

VoLtage

main deViCes

neutraL

rating

PaneL

mounting

PaneL

door

Fuse

HoLders

branCH CirCuit

ProteCtion deViCes

(1-3 PoLe)

PaneL

Feed

oPtionaL Lugs

standard

enCLosure

rating

2 - 42

120/208 V 3P, 4 W

120/240 V 1P, 3 W

277/480 V 3P, 4 W

125, 225, 400 or

600 A MLO

Up to 600 A MCB

or Main Fuse

Pullout

100%

200%

Surface

Flush

Standard

Door-in-door

30 A Class CC

60 A Class J

10 A- 60 A fused

circuit breaker

60 A-200 A

fused pullouts

Sub-fed circuit breakers

>60 A

(not fused)

Top

Bottom

None

Sub-Fed (MLO panels)

Feed-Through

NEMA 1

NEMA 3R

NEMA 4X

To quickly specify the LCP panel,
visit

Littelfuse.com/lcp

and download the Specifier Tool.

Advertising