Q-Tech QT826 Sine Wave User Manual

Page 6

Advertising
background image

Q-TECH Corporation

10150 W. Jefferson Blvd.
Culver City, CA 90232

SIZE

A

CAGE NO.

51774

QT824, QT825 and QT826

Sine-Wave 32 Flat Pack

REV.

E

Page 6 of 10

Group C Inspection1

Group C Electrical Inspections are performed on a 100% basis

NOTE: Samples from Subgroup 1 may be divided and used for Subgroups 3 and 4

Inspections.

SUB-

GROUP

TEST

DESCRIPTION

CONDITION

QTY

1

Vibration

(random)

MI-STD 202 Method 214/ T.C. I-K (46Grms) for 3 minutes

in each plane.

4 parts

(0 failures)

Shock

MI-STD 202 Method 213 T.C. F

(1500g, 0.5ms half-sine pulse) 3 blows each direction of

three axes (18 shocks total)

Electrical Test

Frequency, Output levels, Input Current

@ +25°C & Temp Extremes listed on the Electrical

Specification.

Hermetic Seal

Fine Leak – MIL-STD-883 Method 1014 Condition A1

Gross Leak – MIL-STD-883, Method 1014 Condition C

Electrical Test

Frequency, Output levels, Input Current

@ +25°C & Temp Extremes listed on the Electrical

Specification.

Temperature

Cycling

MI-STD 883, Method 1010, TC B 100 cycles.

Electrical Test

Frequency, Output levels, Input Current

@ +25°C & Temp Extremes listed on the Electrical

Specification

Ambient Pressure

(Non-Operating 2 MI-STD 202 Method 105 T.C. C

Electrical Test

Frequency, Output levels, Input Current

@ +25°C & Temp Extremes listed on the Electrical

Specification

Storage

Temperature

Low Temp.of - 55 (+0, -5) °C

HighTemp.of +150 (+5,-0) °C

Hermetic Seal

Fine Leak – MIL-STD-883 Method 1014 Condition A1

Gross Leak – MIL-STD-883, Method 1014 Condition C

Electrical Test

Frequency, Output levels, Input Current @ +25°C & Temp

Extremes listed on the Electrical Specification

3

Resistance to

Soldering Heat MI-STD 202 Method 210 T.C. B

1 parts

(0 failures)

Hermetic Seal

Fine Leak – MIL-STD-883,Method 1014 Condition A1

Gross Leak – MIL-STD-883, Method 1014 Condition C

Moisture

Resistance

MI-STD 202 Method 106

4

Terminal

Strength (Lead

Integrity)

MI-STD 202 Method 211 T.C. B

1 parts

(0 failures)

Visual Inspection

Hermetic Seal

Fine Leak – MIL-STD-883,Method 1014 Condition A1

Gross Leak – MIL-STD-883, Method 1014 Condition C

Resistance To

Solvents

MI-STD 202 Method 215

Advertising