Comfort Stat CDT901 User Manual

Page 55

Advertising
background image

CDT900 Series Touchscreen Programmable Thermostata

Table 3.installer Setup Menu. (CONTINUES)

Installer Setup

Number

Installer Setup

Name

Settings Notes

0330 Daylight

Savings

1-daylight savings is on (factory setting).

0-daylight savings is off.

Set to 0 in areas that do not

follow daylight savings.

0340

Remote Temperature

Sensor (Outdoor or

Indoor)

0-no remote temperature sensor

1-outdoor temperature sensor for display

only.

2-outdoor temperature sensor for

control.Outdoor sensor used for Heat Pump

Lockout settings. (See Heat Pump
Temperature Lockout section for more

details.)

3-indoor temperature sensor

Defaults and Options depend

on System Type selection.

Indoor Temperature Sensor

uses an averaging network

and does not include on-board

sensor.

0350

Heat Pump

Compressor Lockout

or (Balance Point)

0-no compressor lockout.

15°F (-9.5°C)

20°F (-6.5°C)

25°F (-4°C)

30°F (-1°C)

35°F (1.5°C)

40°F (4.5°C)

45°F (7°C)

Default depends on other

selections. Shown if control is

selected. (See section for
more information.)

54

Advertising
This manual is related to the following products: