BMC Sensor Codes Table

Category 1: Memory related

Sensor

No.

Sensor Name Sensor Type

Sensor Type

code

Sensor Value or Event Type

Event Data 3

0xD1

CPU1_ECC1

Memory ECC Sensor

0x0C

Discrete(0x6F)

0x01: Correctable ECC

0x02: Uncorrectable ECC

0x40: Presence detected

0x00: DIMM_A1, 0x01: DIMM_A2,

0x02: DIMM_A3, 0x03:DIMM_A4,

0x04: DIMM_B1, 0x05: DIMM_B2,

0x06: DIMM_B3, 0x07: DIMM_B4,

0x08: DIMM_C1, 0x09: DIMM_C2,

0x0A: DIMM_C3, 0x0B: DIMM_C4,

0x0C: DIMM_D1, 0x0D: DIMM_D2,

0x0E: DIMM_D3, 0x0F: DIMM_D4

0xD2

CPU1_ECC2

OEM Memory ECC Sensor

(For Intel DP platform only

-- ASUS Z8 series server

MB; -E6 server system)

0xC1

Discrete(0x6F)

0x01: Read ECC error

0x02: ECC Error occurred on a scrub

0x04: Write Parity Error

0x08: Error in Redundant memory

0x10: Sparing Error

0x20: Memory access out of Range

0x40: Address Parity Error

0x80: Byte Enable Parity

0x00: DIMM_A1, 0x01: DIMM_A2,

0x02: DIMM_A3, 0x03:DIMM_A4,

0x04: DIMM_B1, 0x05: DIMM_B2,

0x06: DIMM_B3, 0x07: DIMM_B4,

0x08: DIMM_C1, 0x09: DIMM_C2,

0x0A: DIMM_C3, 0x0B: DIMM_C4,

0x0C: DIMM_D1, 0x0D: DIMM_D2,

0x0E: DIMM_D3, 0x0F: DIMM_D4

0xD3

CPU2_ECC1

Memory ECC Sensor

0x0C

Discrete(0x6F)

0x01: Correctable ECC

0x02: Uncorrectable ECC

0x40: Presence detected

0x00: DIMM_D1, 0x01: DIMM_D2,

0x02: DIMM_D3, 0x03: DIMM_D4,

0x04: DIMM_E1, 0x05:DIMM_E2,

0x06: DIMM_E3, 0x07: DIMM_E4,

0x08: DIMM_F1, 0x09: DIMM_F2,

0x0A: DIMM_F3, 0x0B: DIMM_F4,

0x0C: DIMM_G1, 0x0D: DIMM_G2,

0x0E: DIMM_G3, 0x0F: DMM_G4,

0x10: DIMM_H1, 0x11: DIMM_H2,

0x12: DIMM_H3, 0x13: DIMM_H4,

0x14: DIMM_C1, 0x15: DIMM_C2,

0x16: DIMM_C3, 0x17: DIMM_C4

0xD4

CPU2_ECC2

OEM Memory ECC Sensor

(For Intel DP platform only

-- ASUS Z8 series server

MB; -E6 server system)

0xC1

Discrete(0x6F)

0x01: Read ECC error

0x02: ECC Error occurred on a scrub

0x04: Write Parity Error

0x08: Error in Redundant memory

0x10: Sparing Error

0x20: Memory access out of Range

0x40: Address Parity Error

0x80: Byte Enable Parity

0x00: DIMM_D1, 0x01: DIMM_D2,

0x02: DIMM_D3, 0x03: DIMM_D4,

0x04: DIMM_E1, 0x05:DIMM_E2,

0x06: DIMM_E3, 0x07: DIMM_E4,

0x08: DIMM_F1, 0x09: DIMM_F2,

0x0A: DIMM_F3, 0x0B: DIMM_F4,

0x0C: DIMM_G1, 0x0D: DIMM_G2,

0x0E: DIMM_G3, 0x0F: DMM_G4,

0x10: DIMM_H1, 0x11: DIMM_H2,

0x12: DIMM_H3, 0x13: DIMM_H4,

0x14: DIMM_C1, 0x15: DIMM_C2,

0x16: DIMM_C3, 0x17: DIMM_C4

Advertising