2-3.

Operation

<Installation>

The amplifier should never be placed in areas.

Never block ventilation holes.
Never to exposed to direct sunlight.
Never with high humidity or dust levels.
Never with high ambient temperatures.
Never susceptible to vibration.
Never with poor ventilation.
Never adjacent to heat-generating equipment.

1.

Connect Connects to earth-ground by shorter than 10 feet 16AWG or thicker

cable.

2. Do not remove the case or you may encounter an electric shock.

When the temperature of heat sink exceeds 95 °C the protection circuit is activated and the

output is disconnected from the circuit. Output is automatically restored when the temperature

return to normal operating parameter.

<

Rack Mounting >

To mount the amplifier in a standard 19" equipment rack, use the ear- rack mounting bracket.

Remove 4 screws securing case

Fix the brackets with attached 4 screws.

The length of screws should not exceed

12mm (1/2")

Ear Bracket