Operators Manual

D3804 27

Setting/
Display

D.A.N Options

(

Bold

= Default)

Description

BUFFER

(

BUFFER

)

238

ON

Set to ON

PBLine

(PBLINE)

239 1,2,

3

Use 3

MENU 3

Display

Count

(

COUNT

)

301 .01,.02,.05,.1,.2,.5,

1,2,5,

10

,20,

50,100

Minimum weight change

that is displayed.

Note: If this is too small,

scale will be unstable.

Display Unit

(

LB-KG

)

303

LB

/KG

Unit of measure.

Note: If this changes,

calibration and set-up must

change.

Capacity

(

CAP

)

304

85,000

Maximum capacity of scale.

MENU 4

U-Alarm

(UALARM)

407

1

,2,3,4

Adjust unload alarm setting

CALIBRATION

Setup

Number

(

SETUP

)

871

Quick entry method selects

weigh method 1-4lbs, 5-

8kg, gain 1-9, display

counts 1-9 and capacity

*1000.

Calibration

Number

(

CAL

)

872

Weight displayed at .4mV/V

for these load cells.