RL Series Feature String Nomenclature
:
S
IZ
E
V
L
T
C
O
N
FI
G
A1
A2
A3
A4
B1
B2
B3
1A
1B
1C
1D
2
3
4
5A
5B
5C
6A
6B
6C
7
8
9
10
11
12
13
14A
14B
15
16
17
18
19
20
21
22
23
R L – 1 0 0 – 3 – 0 – B E 0 6 – 3 5 2 : B E B E – D 0 0 – Q F Y – P 0 A – 0 D B B 0 0 0 – 0 0 – 0 B B 0 0 AB 0 B
G
E
N
Model Options
Unit Feature Options
BASE MODEL
SERIES AND GENERATION
RL
UNIT SIZE
045 = 45 Nominal Tons
060 = 60 Nominal Tons
070 = 70 Nominal Tons
075 = 75 Nominal Tons
090 = 90 Nominal Tons
095 = 95 Nominal Tons
100 = 100 Nominal Tons
110 = 110 Nominal Tons
120 = 120 Nominal Tons
125 = 125 Nominal Tons
134 = 134 Nominal Tons
135 = 135 Nominal Tons
150 = 150 Nominal Tons
155 = 155 Nominal Tons
170 = 170 Nominal Tons
180 = 180 Nominal Tons
181 = 181 Nominal Tons
190 = 190 Nominal Tons
210 = 210 Nominal Tons
230 = 230 Nominal Tons
240 = 240 Nominal Tons
VOLTAGE
2 = 230V/3Φ/60Hz
3 = 460V/3Φ/60Hz
4 = 575V/3Φ/60Hz
8 = 208V/3Φ/60Hz
INTERIOR PROTECTION
0 = Standard
A = Interior Corrosion Protection
Model Option A: COOLING
A1: COOLING STYLE
B = Blow-Through, R-410A, Dual Circuited
C = Draw-Through, R-410A, Dual Circuited
D = Blow Through - R-134a Variable Capacity Oil-
Free Magnetic Bearing Centifugal Compressors
E = Draw Through - R-134a Variable Capacity Oil-
Free Magnetic Bearing Centifugal Compressors
F = Blow-Through AHU w/ Vestibule
G = Draw-Through AHU w/ Vestibule
H = Blow-Through AHU w/ Front Control Panel
J = Draw-Through AHU w/ Front Control Panel
M = Blow-Through AHU w/ End Control Panel
N = Draw-Through AHU w/ End Control Panel
R = Blow-Through, R-410A, Independ Circuited
S = Draw-Through, R-410A, Independ Circuited
7 = Blow-Through, R410A VFD Compatible
Compressors
8 = Draw-Through, R410A VFD Compatible
Compressors
A2: COOLING CONFIGURATION
0 = No Cooling
A = Air-Cooled Cond, 4 Row High CFM Evap
B = Air-Cooled Cond, 6 Row High CFM Evap
C = Air-Cooled Cond, 4 Row Low CFM Evap
D = Air-Cooled Cond, 6 Row Low CFM Evap
E = Evap-Cooled Cond, 4 Row High CFM Evap
F = Evap-Cooled Cond, 6 Row High CFM Evap
G = Evap-Cooled Cond, 4 Row Low CFM Evap
H = Evap-Cooled Cond, 6 Row Low CFM Evap
J = Water-Cooled Cond, 4 Row High CFM Evap
K = Water-Cooled Cond, 6 Row High CFM Evap
L = Water-Cooled Cond, 4 Row Low CFM Evap
M = Water-Cooled Cond, 6 Row Low CFM Evap
U = Chilled Water, 4 Row High CFM
V = Chilled Water, 4 Row Low CFM
W = Chilled Water, 6 Row High CFM
Y = Chilled Water, 6 Row Low CFM
Z = Chilled Water, 8 Row High CFM
1 = Chilled Water, 8 Row Low CFM
2 = Non-Compressorized, 4 Row High CFM Evap
3 = Non-Compressorized, 4 Row Low CFM Evap
4 = Non-Compressorized, 6 Row High CFM Evap
5 = Non-Compressorized, 6 Row Low CFM Evap